INSTALLATION MODE

Installation Mode

Installation Mode

On program

Tuner Menu

Max Volume

Winter mode

RC inhibition

Child Lock

Address

Baud rate

Panel protection

AV Auto shut off

Network Standby

On Timer Function

LED light setting

DCR

Network initial

Temperature Error

IP Address

Subnet

Gateway

DNS

Off

Off

63

Off

Off

Off

0

19200

Off

Off

On

Off

Off

Off

>>>

0

000000000000
000000000000
000000000000
000000000000

G2.02 0000

Select

Adjust

MENU

Exit

This LCD monitor allows you to set up the following:

SETTING PROCEDURE

1. Press and hold the GREEN button on the remote control for 5

seconds . (Installation Mode will appear)

2. Use the 5 or 6 button to highlight each option, use the 1 or

2 button to adjust each option . Press the MENU button to exit
the mode .

On Program

Select ON program using the 5 or 6 button, select the start up
position using the 1 or 2 buttons .
(Off/AV1/RGB/AV2/AV3/PC/DVI or Network)

Max Volume

Select Max volume using the 5 or 6 button, use the 1 or 2
buttons to set the maximum volume required .

Winter mode

This Function can be activated when the LCD monitor is used dur-
ing cold temperature conditions, approximately 38˚F/4˚C or below to
maintain picture performance .
Using the 5 or 6 button select winter mode, once highlighted you
can select ON or OFF by pressing the 1 or 2 button .
IMPORTANT: The AC cord should not be disconnected during the
operation of Winter mode function .
When in winter mode, power consumption is higher than normal
standby consumption . This is entirely due to the operation of heating
circuitry . We strongly recommend to turn off Winter mode when the
ambient temperature is above 38˚F/4˚C.

RC inhibition

You can prevent unwanted remote control operation by selecting RC
Inhibition .
Select using the 5 or 6 button . Press the 1 or 2 button to
select On or Off .
To re-instate RC operation press and hold the green button on the
remote control and select RC inhibition OFF .

Child Lock

You can prevent unwanted operation of the LCD monitor via the
buttons on the rear of the monitor .
Select using the 5 or 6 button . Press the 1 button to select
On or OFF. The “Child Lock” OSD will appear if buttons are pressed
when child lock is On.

Standby operates normally when childlock is set “On”.

Address

Set the address for the LCD monitor (0 ~ 999) .

Setting the monitor address in RS232 mode

Each monitor can have a specific Address, which helps command
that monitor individually and will not effect to other monitors con-
nected to a controlling PC Address format command .
The addressing format command is used for operating multiple
monitor sets from a single PC via the RS232C command line .

Baud rate

Select Baud rate using the 5 or 6 button . To set transmission
speed RS232 or LD-NET communication for 19200 or 9600 Baud rate
by pressing the 1 or 2 button .

Panel protection

To prevent image sticking which may occur showing still picture for a
long time, select “Panel Protect” using the 5 or 6 button, once
highlighted you can select ON or OFF by pressing the 1 or 2
button .

AV Auto shut off

With no picture input signal to AV1, RGB, AV2(YPbPr), AV3, DVI,
Network, set turns off automatically. Select “AV Auto Shut Off” using
the 5 or 6 button, once highlighted you can select On or Off by
pressing the 1 or 2 button .

Network Standby

You can save power consumption selecting “Off” at Network Standby
in Installation mode, RS232C do not functional. To make them func-
tional, select “ON” in this menu.

On Timer Function

You can save power consumption selecting “Off” at On Timer function
in Installation mode . On Timer in Time menu does not functional . To
make them functional, select “ON” in this menu.

LED Light setting

Select LED Light setting using the 5 or 6 button, once highlight-
ed you can select On or Off by pressing the 1 or 2 button .

DCR

The picture contrast improved while DCR is ON . Select DCR using
the 5 or 6 button, once highlighted you can select On or Off by
pressing the 1 or 2 button .

Network Initial

This function is not used .

Temperature Error

The recorded number of abnormal temperature is occurred is indi-
cated here .

IP Address/Subnet/Gateway/DNS

This function is not used .