Heater location and installation, Diagram 1 – Soleus Air Industrial Utility Heater HI1-50-03 User Manual

Page 6

Advertising
background image

HEATER LOCATION AND INSTALLATION

Install the heater out of traffic areas maintaining the required clearances below. The direction of air flow shold
not be restricted by anything and the air flow should not blow directly at exposed walls. When more than one
heater is used in an area, the heaters should be arranged so that the air discharge of each heater supports the air
flow of the other heater(s) to provide optimal circulation of warm air

Note: Min. clearance to ceiling when
not using mounting brackets is 1 5/8”

14.37”

15.7”

5 1/2”

11.29”

MINIMUM

DISTANCE

TO WALL

13”

24”

MINIMUM

DISTANCE

FROM

DISCHARGE TO

ANY OBJECT

MINIMUM

DISTANCE TO

FLOOR 6 ft.

MAXIMUM MOUNTING HEIGHT FOR:

Vertical air delivery unit = 11 ft.

Horizontal air delivery unit = 8 ft.

FRONT VIEW

SIDE VIEW

MOUNTING
LOCATION

DIAGRAM 1

6