Construction:

Dimensions:

7.0 x 3.6 x 4.0 in. (H x W x D)
(17.8 x 9.1 x 11.2 cm.)

4501-25/26

8.4 x 4.4 x 3.9 in. (H x W x D)
(21.3 x 11.2 x 9.9 cm.)

Weight:

2.2 lb. (1.0 Kg) Al
4.6 lb. (2.1 Kg) SS

4501-25/26

3.0 lb. (1.3 Kg) Al
5.0 lb. (2.3 Kg) SS

Enclosure:

Aluminum, Stainless Steel

Approvals and Warranty:

Hazardous Location: Explosion proof, NEMA 4X
FM:

Class I, Div. I, Groups B, C, D
Class II, Div. I, Groups E, F, G

CSA:

Class I, Div. I, Groups B, C, D
Class II, Div. I, Groups E, F, G

4501-05 FM Performance Approval:

4501-05 Approval FM ISA-92.0.01,
Part I-1998 and FM 3600

Limited warranty:

2 years

Specifications subject to change without notice

(1) Other ranges available

(2) To 90% range

(3) Ammonia and HF sensor
requires electrolyte recharge
up to year

Output:

Display:

LCD, 2-line, 16-characters

Signal Output:

2-wire sensor powered analog 4-20 mA
(Trouble: 3.6 mA)

Loop Resistance

800 ohm

Electrical Data:

Power consumption: 0.2 watts
Connection type:

2-wire, loop-powered

Input voltage:

24 VDC nominal: 14-30VDC

RFI/EMI Protection:

EN50081-2, EN50082-2

Operating Range:

Ambient Temp Range:
Standard:

-4

o

to 122

o

F(-20

o

to 50

o

C)

4501-25/26

+14

o

to 113

o

F(-10

o

to 45

o

C)

Extended Temp:

Sensor and 4-20 mA will continue to
operate to -40

o

F (-40

o

C) but the LCD

display will decay over time if exposed
to temperatures below -4

o

(-20

o

C) for

significant time (not for 4501-25)

Storage Temp:

-4

o

to 122

o

F(-20

o

to 50

o

C)

Relative Humidity:
Standard:

15-90%

4501-25/26:

20-90%

Specifications

:

P e rfo rm a n c e

M a x . G a s R a n g e (1 )

R e s o lu tio n

R e s p o n s e T im e (2 )

S e n s o r L ife

4 5 0 1 -0 3 O

2

0 - 2 5 % V o l

0 .2 % V o l.

< 1 0 S e c o nd s

2 0 M o nths

4 5 0 1 -0 4 C O

0 - 1 2 0 0 P P M

0 .5 P P M

< 2 5 S e c o nd s

2 Ye a rs

4 5 0 1 -0 5 H

2

S

0 - 1 0 0 P P M

0 .1 P P M

< 3 0 S e c o nd s

2 Ye a rs

4 5 0 1 -0 6 C l

2

0 - 1 0 P P M

0 .1 P P M

< 6 0 S e c o nd s

2 Ye a rs

4 5 0 1 -0 8 C lO

2

0 - 3 P P M

0 .1 P P M

< 6 0 S e c o nd s

2 Ye a rs

4 5 0 1 -1 0 S O

2

0 - 1 0 0 P P M

0 .5 P P M

< 2 0 S e c o nd s

2 Ye a rs

4 5 0 1 -1 2 N O

2

0 - 2 0 P P M

0 .2 P P M

< 3 5 S e c o nd s

2 Ye a rs

4 5 0 1 - 2 5 N H

3

0 - 1 0 0 P P M

1 .0 P P M

< 3 0 S e c o nd s

(3 )

4 5 0 1 - 2 6 H F

0 - 1 0 P P M

1 .0 P P M

< 9 0 S e c o nd s

(3 )

Ordering
Information:

High Capacity Calibration Accessories
1250-01

Gas Sensor Calibration Kit, Type A (CO, H

2

S)

1250-02

Gas Sensor Calibration Kit, Type B (SO

2

, NO

2

)

1250-03

Gas Sensor Calibration Kit, Type C (Cl

2,

ClO

2

)

1260-00

Gas Cylinder, Air (Type A) 105 liters

1260-04

Gas Cylinder, Carbon Monoxide, 100 ppm, Type A

1260-05

Gas Cylinder, H

2

S in N

2

, 25 ppm Type A

1260-06

Gas Cylinder, Chlorine, 5 ppm, Type C

1260-10

Gas Cylinder, Sulfur Dioxide, 50 ppm, Type B

1260-12

Gas Cylinder, Nitrogen Dioxide, 10 ppm, Type B

1260-13

Gas Cylinder, Carbon Monoxide, 1000 ppm, Type A

1260-45

Gas Cylinder, H

2

S in N

2

, 10 ppm, Type A

9210-00

Calibrator, Permeation tube

9211-09

Permeation Tube, Ammonia, NH

3

SPX 27057 Kit, Sensor Recharge, for 4501-25

Rev. 5/2012

Accessories
5311-00

Rainshield

5311-02

Rainshield with calibration port

Calibration Accessories
5358-01

Calibration Adapter, Standard

5360-00

Calibration Gas Delivery Fitting

5358-51

Calibration/Configuration Magnetic
Tool, 4501-XX

2-Wire Toxic Gas Sensor Module Model 4501-XX

Sierra Monitor Corporation 1991 Tarob Ct. Milpitas, CA 95035 USA (408) 262-6611 (800) 727-4377 Fax: (408) 262-9042

Visit our website: www.sierramonitor.com E-mail: [email protected]

4501 Series

- 03 = O

2

- A1 = Aluminum Enclosure, 3/4” NPT

- 04 = CO

- A2 = Aluminum Enclosure, M20 x 1.5

- 05 = H

2

S

- S1 = Stainless Steel Enclosure, 3/4” NPT

- 06 = Cl

2

- S2 = Stainless Steel Enclosure, M20 x 1.5

- 08 = ClO

2

- 10 = SO

2

- 12 = NO

2

- 25 = NH

3

- 26 = HF

Model -