Page F-5

X-Rack Master Module

F.5 Calibration Information

The X-Rack Master module is factory calibrated and should only need calibration if a potentiometer or

other component has been replaced or if it is suspected that there is a problem with calibration.
In each of the following instructions it is assumed that the lid of the X-Rack has been removed and that

power has been applied. It is also assumed that, unless otherwise specified, all switches are released and

all front panel potentiometers are at unity or minimum position as appropriate. The required accuracy for

each adjustment will be specified along with the target value. All level and distortion measurements

should be made with audio-band 20Hz to 20kHz filters unless otherwise specified.
All presets are accessible from the top of the unit.

F.5.1 Mix Level Tracking

Equipment Required:

Calibrated audio oscillator and audio level meter

Test Signal:

1kHz sinewave @ +24dBu

Input and Output:

Oscillator to Insert Return Left

Output to the audio level meter from Mix Bus Output (use Left or Right

as instructed below)

Unit Setup:

Select ‘INS’ and set ‘MIX LEVEL’ to centre.

Adjustment:

1. Measure Mix Bus Output Left and note the reading.
2. Connect the oscillator to Insert Return Right.
3. Measure Mix Bus Output Right and adjust VR6 (‘TRACKING’) for a level

which matches that measured in step 1.

F.5.2 Meter Level

Equipment Required:

Calibrated audio oscillator and audio level meter

Test Signal:

1kHz sinewave @ +24dBu

Input and Output:

Oscillator to Insert Return Left

Output to the audio level meter from Follow Mon Output (use Left or

Right as instructed below)

Unit Setup:

1. Select ‘INS’ and set ‘MIX LEVEL’ to maximum.
2. Select

Adjustment:

1. Measure the Left ‘Follow Mon’ Output. Adjust the oscillator level to

obtain +24dBu, if necessary.

2. Adjust VR5 (‘0dB LEFT’) so that that the top left hand ‘red’ LED on the

bargraph meter just illuminates.

3. Connect the oscillator to Insert Return Right.
4. Measure the Right ‘Follow Mon’ Output. Adjust the oscillator level to

obtain +24dBu, if necessary.

5. Adjust VR4 (‘0dB RIGHT’) so that that the top right hand ‘red’ LED on the

bargraph meter just illuminates.