Sanyo ML414 User Manual

Cell type ml414 specifications, Typical characteristics

Advertising
background image

2.6

2.8

3.0

3.2

0

0.5

1.0

Charging Conditon(discharged cell to 2.0V)

Load:3kohm

Temp.: 23

Charging Duration : 30hours

Discharging condition

Load : 300kohm

Temp.: 23

End Voltage : 2.0V

0

50

100

150

200

1.0

1.5

2.0

2.5

3.0

3.5

Discharge Condition

Load : 300kohm

Temp.: 23

after 20days storage at 60

Cell Type ML414

Specifications

1.0mAh

3V

0.005mA

Continuous

*2

0.2mA

Pulse

*3

0.6mA

Discharging Depth of 5%

3000

Discharging Depth of 20%

300

Constant Voltage Charge

3.1±0.15V

Hight Temperature

2.95±0.15V

-20℃~60℃

0.07g

Diameter(D)

4.8mm

Height(H)

1.4mm

Dimensions

Charging Method

Nominal Capacity

*1

Nominal Voltage
Standard Charge/Discharge Current

Weight

Charge/Discharge Cycle Characteristics

Max. Discharge Current

Temperature Range

Typical Characteristics

Discharge Characteristics after Storage of ML414

Ce

ll Vo

lta

ge(V)

Duration(hour)

Di

sc

ha

rg

e Ca

pa

ci

ty

(m

A

h)

Charging Voltage(V)

Temperature Characteristics of ML414

Charging Voltage vs. Capacity of ML414

Ce

ll Vo

lta

ge(V)

Duration(hour)

Nominal capacity is determined to an end voltage of 2.0V when the battery is allowed to
discharge at a standard current level at 23

o

C.

*1

Current value is determined so that 50% of the nominal capacity is obtained with an end
voltage of 2.0V at 23

o

C.

*2

o

C

o

C

Current value for obtaining 2.0V cell voltage when 15sec. pulse is applied
at 50% discharge depth at 23

o

C.

*3

o

C

o

C

0

50

100

150

200

1.0

1.5

2.0

2.5

3.0

3.5

-20

o

C

23

o

C

60

o

C

Charging Voltage : 3.0V

Load : 300kohm

D

H

Advertising