Stearns Recreational 4430 User Manual

Page 15

Advertising
background image

15

2. Oral Inflation Leak Test - This test should be performed

every two months and at the start of each season. Inflate

buoyancy chamber using the oral inflation valve and leave to

rest for 16 hours. When buoyancy chamber remains firm and

full of air there is no leakage and chamber is operational. If

the chamber deflates during this leak test, it is no longer in

operational condition and should not be used. Some types of

leaks can be repaired by a certified Stearns Repair Facility,

while others are not repairable. If the PFD leaks, either return

to certified Stearns Repair Facility for evaluation and repair, or

discard the PFD.

3. Function Test of Oral Valve - With the PFD inflated, remove

the dust protection cap, and test the valve by pushing it down

using the tab provided on the cap (refer to Page 10). The

valve should depress easily, and when depressed, air should

escape. When released the valve should automatically return

to the closed position and reseal.

REARMING KIT(S)

Use replacement kit no. 0925. See Rearming Instructions on

pages 11 and 12.

CARE AND CLEANING INSTRUCTIONS

Drying – If the device is wet, place on a coat hanger to allow

thorough drying. Do not place in direct sunlight to dry. Do not use

any heat source or place on radiator.

Cleaning – Damp wipe only with mild detergent recommended for

synthetic fabrics. Remove grease and oil immediately. After every

use rinse well with fresh water. Read instructions provided on the

device.

• DO NOT MACHINE WASH

• DO NOT MACHINE DRY

• DO NOT DRY CLEAN

• DO NOT USE SOLVENT BASED CLEANERS

• DO NOT BLEACH

Revised: 2006-05-08