Normal shutter, Setting of the normal shutter, External trigger shutter – Sony XC-EU50 User Manual

Page 9: Setting of the external trigger shutter, 9mode setting

Advertising
background image

9

Mode Setting

Normal Shutter

This mode provides continuous video output with the
electronic shutter selected by switches to capture a
high-speed moving object clearly.

Setting of the Normal Shutter

Using the DIP switches on the rear panel

* If you set the mode to flickerless, the positions of DIP switches 1 to 3 are

optional.

Notes

• The positions of DIP switches 6 and 7 are optional.
• The DIP switch 5 position is optional. (The field

setting is recommended.) The field setting can obtain
a sensitivity that is twice that of the frame setting.

External Trigger Shutter

By inputting an external trigger pulse, the camera is
able to capture fast-moving objects clearly.
Set DIP switches 6, 7, and 8 on the rear panel to Mode
1 or Mode 2 (See the table below).
When you set the trigger pulse width to 1/3 of a second
or more, the output signal changes to the normal
VIDEO signal.

There are two modes for timing in which a video
signal is obtained.
• Mode 1 (Non-reset mode)
In this mode, a video signal synchronized with a VD
signal is output after a trigger pulse is input.

– A video signal is synchronized with the external

VD signal when an external HD/VD signal is input.

– A video signal is synchronized with an internal VD

signal when no external HD/VD signal is input.

• Mode 2 (Reset mode)
In this mode, an internal VD is reset, then an internal
video signal is output after trigger pulse input after a
certain period of time.

For details of each timing chart, see pages 13 to 20.

Setting of the External Trigger
Shutter

You can set the shutter speed with the DIP switches or
using the trigger pulse width.

To set the shutter speed with the trigger pulse width, see
page 8.

Using the DIP switches on the rear panel

1/125

1/250

1/500

1/1000

Shutter

OFF

1/2000

1/4000

1/10000

(EIA)

1/8000
(CCIR)

Flickerless*
(EIA: 1/100

CCIR: 1/120)

Mode 1 (Non-reset mode)

1/125

1/250

1/100

(EIA)*

1/120

(CCIR)*

1/500

1/1000

1/2000

1/10000

(EIA)

1/8000
(CCIR)

1/4000

(Unit: second)

(Unit: second)