Operating the c•que 8, Balance control, Master level meter – Samson Cque 8 User Manual

Page 9: Master inject, 2 channel/stereo switch

Advertising
background image

7

Operating the C•que 8

Repeat the previous step for all Channels that have headphones connected, making sure to start the
VOLUME knob completely counterclockwise and then slowly raising it until the desired level is achieved.
If you have connected different models of headphones to the various Channel Headphone jacks, you
may find that some require more gain than others to achieve the same volume. This kind of disparity will
occur if the various headphones have different impedances. The lower the impedance, the louder the
headphone will sound compared to another, higher impedance headphone at the same VOLUME setting.
Another factor affecting headphone loudness is called sensitivity. This is generally measured by deter-
mining the decibel (dB) level generated by 1 mW of power input. The higher the dB rating, the louder the
headphone. See the Reference chart on page 13 of this manual for more details.

To achieve optimum signal-to-noise ratio, the master VOLUME should generally be set as high as possi-
ble, short of audible distortion. However, if this results in your getting blasted with signal even though the
channel volume is near minimum, you’ll need to decrease the Master Volume while raising one or more
channel volume levels. Conversely, if you find that you have to raise one or more headphone Channel
Volume knobs to maximum or near maximum to achieve the desired level, try increasing the master
Volume level while decreasing the channel volume(s).

SETTING UP THE C•que 8 - Continued

C•que 8 Master Section

Master Volume

The C•que 8’s master VOLUME control is used to adjust the input signal connected to the main Left and Right
inputs. In addition, the master VOLUME control adjusts the level of the signal inserted in the INJECT, which is
summed with the MAIN Left and Right input signal.

Balance Control

The C•que 8’s main channel has a BALANCE control,
which controls how much signal is sent to the left or right
headphone outputs. The control knob has a center detent
which indicates that the left and right sides are balanced.
In 2 Channel mode, the signal becomes mono and the
BALANCE knob adjusts the level balance between the
signals connected to the LEFT inputs and signals con-
nected to the RIGHT inputs. (For more information on 2-
Channel mode, see the section “Mixing Signals in 2
Channel Mode” found on page 9 of this manual.)

Master Level meter

The C•que 8’s master section includes a 6 segment LED LEVEL meter which monitors the input level from the
MAIN Left and Right Inputs in Decibels (dBs) from –24 to OL (overload). If the LEVEL meter displays an OL sig-
nal, then turn down the signal using the master VOLUME control.

Master Inject

The C•que 8’s MASTER INJECT is a TRS input (Tip, Ring, Sleeve), that allows a second stereo signal to be
inserted and summed together with the MAIN Left and Right signals. You can use a stereo signal from your mix-
ers bus outputs or auxiliary sends to balance the mix between two stereo signals like rhythm tracks and vocals.

2 Channel/Stereo switch

The 2 CH/STEREO switch is used to change between the C•que 8’s two global operating modes, 2-Channel and
Stereo. In Stereo mode the left and right Line inputs are mixed with the left and right Inject inputs, in stereo, with
the Balance knob controlling the left and right panning. In 2-Channel mode, the left and right LINE inputs are
mixed with the left and right INJECT inputs into a single mono signal with the BALANCE knob controlling the level
difference between the LEFT and RIGHT inputs.

MAIN

INJECT

VOLUME

BALANCE

2 CH

STEREO

SH

SH

OL

0

-6

-12

-18

-24

0

10

L

R

3

1

2

1

2

3

4

4

5

5

Advertising