Schumacher SE-70MA User Manual

Page 10

Advertising
background image

6

Recommended minimum AWG size for extension cord:

8.3

AC input rating,

amperes*

AWG size of cord

Length of cord, feet (m)

At

least

But less

than

25

(7.6)

50

(15.2)

100

(30.5)

150

(45.6)

0

2

18

18

18

16

2

3

18

18

16

14

3

4

18

18

16

14

4

5

18

18

14

12

5

6

18

16

14

12

6

8

18

16

12

10

8

10

18

14

12

10

10

12

16

14

10

8

12

14

16

12

10

8

14

16

16

12

10

8

16

18

14

12

8

8

18

20

14

12

8

6

*If the input rating of a charger is given in watts rather than in amperes, the

corresponding ampere rating is to be determined by dividing the wattage rating by

the voltage rating - for example:

1200 watts/120 volts = 10 amperes

ASSEMBLY INSTRUCTIONS

9.

No assembly required

CONTROL PANEL

10.

NOTE: Not all switches and LED’s are available on all models.
Ammeter

The Ammeter indicates the amount of current, measured in amps, that is being

drawn by the battery. As a battery takes on a charge, it draws less current from

the charger. Correspondingly, the meter will show less current being drawn by

the battery. When the current stops decreasing, the battery is charged. The

start area of the meter indicates a high rate of current being drawn from the

charger. When cranking an engine, the meter needle will be at the extreme

right side of the start area. The 2 amp charge rate may indicate some activity

on the meter, although the meter does not have the resolution to display this

low rate. For the 2 amp charge rate, a triangle has been provided. Its accuracy

has been calibrated for use with small batteries.

Advertising