Troubleshooting (continued) – Sony ICD-ST20 User Manual

Page 58

Advertising
background image

58

GB

Symptom

You cannot erase a
message.

You cannot
add a recording or an
overwrite recording.

Recording is
interrupted.
Noise is heard.

Recording level is
low.

Recording level is
unstable (when
recording music, etc.).
Recording is
interrupted (when
recording from an
external device).

Remedy

•The message or the folder which contains the

message is set to “Read-only“ in the computer.
Display the message using Windows Explorer
and remove the check for “Read-only“ under
“Properties“.

•The remaining memory is too short. The

overwritten part will be deleted after the
overwriting part finishes recording. Therefore,
you can only overwrite within the remaining
recording time.

•At a factory setting, REC-OP is set to OFF.

Display the menu and set the REC-OP to ON
(page 50) .

•The advanced VOR function (page 14) is

activated. Set the VOR to OFF.

•An object, such as your finger, etc., accidentally

rubbed or scratched the unit during recording
so that noise was recorded.

•The unit was placed near an AC power source,

a fluorescent lamp or a mobile phone during
recording or playback.

•Plug of the connected microphone was dirty

when recording. Clean the plug.

•The i (headphones) plug is dirty. Clean the

plug.

•SENS (microphone sensitivity) is set to L.

Display the menu and set SENS to H or M
(page 52).

•This unit is designed to automatically adjust

the recording level when recording meetings,
etc., and is not suitable for music recording.

•If you use a connecting cable without register

to connect the sound source to the IC recorder,
sound may be recorded interrupted. Make
sure to use a registered connecting cable.