Safety instructions

̈

Never open electronic devices! This must only be done by
authorised personnel and is all the more important for current-
carrying units.

̈

As far as possible, use your SKM 3072-U in dry rooms only. When
you are using the SKM 3072-U outside, it must be protected against
direct moisture. In outdoor applications, always use a windshield.

̈

Use a damp cloth for cleaning your SKM 3072-U. Do not use any
solvents.

23

Technical Data / Dimensions

RF output power

typ. 30 mW

Transmission frequencies

1- 32

Frequency range

470 - 960 MHz

Frequency preparation

PLL synthesizer

Max. switching bandwidth

32 MHz

Frequency deviation

≤ 10 kHz

Spurious emission

≤ 4 nW

Modulation/pre-emphasis

wideband FM/50

µs

Nominal/peak deviation (1kHz)

± 40 kHz/± 56 kHz

Noise reduction system

HiDyn

plus

AF frequency response

80 - 18,000 Hz

Signal-to-noise ratio

110 dB(A)

THD (1 kHz/nom. dev.)

≤ 0.3 %

Sensitivity

adjustable in 4 steps of 10 dB

Max. sound pressure level

154 dB SPL (ME 3005 E)

Power supply

9 V alkaline, IEC 6 LR 61
(or rechargeable accupack)

Power consumption
at nominal voltage

approx. 50 mA

Operating time

with alkaline battery

approx. 8 h

with rechargeable battery

approx. 2 h

Dimensions in mm

255 x 50

Weight incl. battery

approx. 350 g

Supply schedule SKM 3072-U

1 SKM 3072-U hand-held

transmitter with ME 3005 e
mic head

1 9 V PP3 battery
1 MZQ stand adaptor
8 colour-coded protection caps
1 storage case
1 operating instructions

Supply schedule SKM 3072-U-x

1 SKM 3072-U hand-held

transmitter with ME 3005
mic head

1 9 V PP3 battery
1 MZQ stand adaptor
8 colour-coded protection caps
1 storage case
1 operating instructions

21

Error checklist

̈

Transmitter does not work:

Battery is flat, replace the battery! (

u

chapter 8), battery is not

inserted or inserted the wrong way round. Transmitter is defective
(=> send transmitter to a Sennheiser service department!).

̈

No transmission:

Receiver or transmitter are not switched on or transmission
frequency does not agree with receiving frequency.

̈

Short hissing noise or short interruption:

Position of receiving antennæ is unfavourable. Make sure that there
is a “free line of sight” between the transmitter and the antennæ.

̈

Microphone gain too low / microphone overmodulated :

Sensitivity adjusted too low / too high
(=> adjust sensitivity!

u

chapter 15).

̈

After switch-on, the display first indicates “3072-U“ and then
“LoBAt”,the transmitter switches off:

Remaining battery capacity is not sufficient for operation
(=> replace battery!

u

chapter 8).

̈

Transmitter switches off during operation:

After “

LoBAt

” – alternating with the display for frequency/channel

number – has been shown for a certain amount of time, the battery
has become completely flat, the transmitter has switched off
(=> replace battery!

u

chapter 8).

̈

Transmitter cannot be switched off:

“Lock mode” function is activated. “

Loc

” is briefly indicated on

the display (=> deactivate “lock mode“ function!

u

chapter 18).

̈

Transmitter cannot be switched to “CHxxx”:

No channel number is entered, “

CH---

” is briefly indicated,

transmitter switches back to frequency display (=> enter a channel
number!

u

chapter 17).

̈

Strong twittering:

Two transmitters operate on the same frequency, the preselected
frequency is subject to interference (=> change the transmission
and receiving frequency!