Select, Residential gas water heaters – State Industries 201 Series User Manual

Page 2

Advertising
background image

For complete information on limited warranties, consult written warranty,
or contact the State Customer Care Center, 1-800-365-0024.

State Industries, Inc. reserves the right to make product changes or improvements without prior notice.

Recoveries are rounded to nearest gallon.

For 10-Year Tank and 6-Year Parts Warranty, change "6" to "X" in Model Number (GSX 40 YBRT).

Water Connections – 3/4" male on all models.

When ordering Propane, change "Y" to "H" in model number (GS6 40 HBRT).

External heat trap nipples are factory-installed on all models.
† Propane Gas – 40,000 for 50-gallon short, 37,000 for the 50-gallon tall,
36,000 input for 40-gallon models and 32,000 for 30-gallon models.

SELECT

®

Residential Gas Water Heaters

For more information on Select

®

contact:

State Water Heaters

500 Tennessee Waltz Parkway, Ashland City, TN 37015

800.365.0024 Toll-free USA

www.statewaterheaters.com

SRGSS02408

R E S I D E N T I A L

State FVIR design meets the American National Standards Institute standards (ANSI Z21.10.1 - CSA 4.1) that deal with
the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline.

Feature a sealed combustion chamber with air intake filter and a flame arrestor built into the water heater base. In addition, a thermal
cutoff (TCO) device, is designed to shut off gas flow to the burner and pilot if
poor combustion is detected.

Flammable Vapor Ignition Resistant (FVIR) Water Heaters

If flammable vapors accidentally enter the
combustion chamber, the arrestor is designed
so flames burn off the top surface and can not
escape down through the arrestor.

A. Industry standard thermopile
B. Large View Port for easy burner inspection
C. 360

0

combustion air filter

D. Thermal Cutoff (TCO) with manual reset

Maximum Hydrostatic Working Pressure: 150 PSI.

When ordering top-mounted T&P Valve, add "G" to model number (GS6 40 YBRT G).

Propane (LP) models are Series 201

BTU INPUT RECOVERY

DRAFT

SHIPPING

PER HOUR 90°F RISE

A B C D E F

HOOD

WEIGHT

NATURAL† GALLONS

OUTLET

(LBS)

DIMENSIONS IN INCHES

58-1/4

18

13

51-3/4

138

TALL MODELS

SHORT MODELS

1

PEAK

DEMAND

OUTPUT

(1st Hour

Rating

Gallons)

APPROX

ENERGY

FACTOR

GALLON

CAPACITY

FOAM

THICK-

NESS

(Inches)

MODEL

NUMBER

20

13

8

50-1/4

3 or 4

153

60-3/4

1

41

40,000

50

.58

88

GS6 50 YBRT

57

41

61-3/4

Revised April 2013

50

1

36

35,500

30

.61

60

GS6 30 YORS

GS6 30 YORT

18

13-1/2

8

46-3/8

40

3 or 4

113

61-1/2

1

36

35,500

30

.61

67

16

13

8

58

52

3 or 4

112

51-1/2

1

41

40,000

40

.59

66

GS6 40 YBRS

20

13

8

47-3/4

41

3 or 4

135

Low Lead Content

300/301 Series

B

A

F

D

1/2" GAS
CONNECTION

VALVE

C

COLD
CONNECTION

E

HOT
CONNECTION

ANODE ROD
(OPTIONAL T&P
LOCATION)

GS6 50 YBRS

93

.61

50

40,000

41

2

53-1/4

49-1/2

24

13-1/4

8

42-1/2

3 or 4

175

255867_SRGSS02408.indd 2

255867_SRGSS02408.indd 2

4/10/13 11:49 AM

4/10/13 11:49 AM

Advertising