FCC CAUTION:

To assure continued compliance, (example-use only shielded interface cables

when connecting to computer or peripheral devices). Any changes or modifications not expressly

approved by the party responsible for compliance could void the user’s authority to operate this

equipment.

OVERCOMING GROUND LOOP PROBLEMS

If the amplifier is mounted in a rack unit (Use rack mount part # PBM-RK2), or is used with
equipment having its own ground, it is necessary to ensure that ground loops and the associated
problems of hum on the output signal are not introduced by the ground wiring. (see warning)

WARNING

To overcome this problem if it occurs, the electrical and the mechanical ground on the amplifier
may be separated by completely removing the wire connecting the power source to ground.
CONSULT AN ELECTRONICS TECHNICIAN TO ACCOMPLISH THIS TO AVOID POTENTIAL
PERSONAL INJURY OR A HAZARDOUS CONDITION.

SPEAKER CONNECTION

The rear panel of the amplifier contains a 7 screw terminal strip for connection of speakers.
BE CAREFUL TO CONNECT SPEAKERS PROPERLY, see impedance and line voltage instructions
below.

The speaker lines are to be connected directly between the appropriate COM terminal on the 7 screw
terminal strip and the terminal corresponding to the impedance of the speaker(s) or of the line voltage
selected. (70V or 25V)

For 4, 8 and 16 OHM CONNECTIONS (refer to figure 3).
Connect the cables to the terminals on the 7 screw terminal strip provided. Use the screw terminals
which correspond to the impedance of the speaker(s). One lead must always be connected to the
COM. This is just an example. If in doubt consult a qualified technician.

(+)

(+)

(+)

(+)

TWO 8 SPEAKERS

(IN PARALLEL)

TWO 4 SPEAKERS

(IN SERIES)

FIGURE 3