ELECTROMAGNETIC LOCK Installation Manual

Page 3

Filler
Plate*

Standard
Mounting

"Z"
Bracket

For Inswing Doors

"L" Bracket

* Note: may require more

than one filler plate.

12345678

12345678

12345

12345

Power

Supply

Control

Device

+
-

Voltage Selection

12VDC

Magnet set for 12VDC

operation as supplied

from factory.

Position a jumper over the

two middle pins for 24VDC

operation.

24VDC

Important note:

Check jumper settings before connecting the

lock to the 24VDC input power. Damage to the

lock may result from incorrect jumper settings.

Sexnut tube

Sexnut

bolt

This side drill

16mm only

Drill a 8mm

hole thru door

Armature

Screw

Steel and

Rubber

washers

(as

needed)

Armature

HOLLOW METAL DOOR

Drill an 8mm hole thru door. From sexnut

bolt side only, enlarge the 8mm hole to

16mm.

Drill an 8mm hole thru door. From sexnut

bolt side of door, drill 12.7mm (1/2") hole,

25mm (1") in depth.

Drill a 6.8mm dia. hole and tap for

M8 x 1.25 thread.

Sexnut

bolt

Drill 12.7mm

(1/2")

Drill a 8mm

hole thru door

Armature

Screw

Armature

SOLID CORE DOOR

Armature Screw

Tap M8 x 1.25 Thread

REINFORCED DOOR

Armature

FIG.

1

FIG.

2

FIG. 3

12345

12345

ENFORCER

Power Cable

To Magnet

Voltage Selection

12VDC

Magnet set for 12VDC

operation as supplied

from factory.

Position a jumper over the

two middle pins for 24VDC

operation.

24VDC

INPUT

POWER

ENFO

RC

ER

Control

Device

Power

Supply

+

-

+
-

E-941SA-600

E-941SA-1200

Power Cable

To Magnet

Steel and

Rubber washers

(as needed)

Steel and

Rubber washers

(as needed)

(E-941SA-600 &

E-941SA-1200 only)

+

-

INPUT POWER

(Z/L brackets are not available for E-941SA-300.)