Introduction, Connection – Sim2 Multimedia HTL40 User Manual

Page 3

Advertising
background image

SIM2 HTL40

RS-232C CONTROL SPECIFICATIONS

3

1. Introduction


This document describes the communication and data formats used to control SIM2 HTL40 via RS-232C

port.

2. Connection


Switch off your Personal Computer and HTL40 before connecting RS 232C cable.

Use a standard serial cable with 9 pin female to the Personal Computer and 9 pin male to the HTL40: pin 2
connects to pin2, pin 3 to pin 3 and pin 5 to pin 5.

SIM2 HTL40 RS-232C Port is described as follows.

SIM 2 HTL40 RS-232C Control Port:

Pin No

Signal

Definition

1 N/A Not

used

2 TD Transmit

data

3 RD Receive

data

4 N/A Not

used

5 GND

Ground

6 N/A Not

used

7 N/A Not

used

8 N/A Not

used

D-SUB 9-pin

(female)

5

1

9

6

9 N/A Not

used

Switch on the Personal Computer and, after start up, switch on the HTL40.

Load a suitable communication software onto your Personal Computer, and set the Serial Port Parameters as
shown below.

Communication Parameters:

Parameter

Value

Transfer Rate

19200 bps

Data Bits

8

Parity Bit

None

Stop Bit

1

Flow Control

None

Set Send Mode and Read Mode to HEX.

Advertising