Sierra Monitor Corporation SMC Auto Switch (Solid State) D-M9NA User Manual

Page 2

Advertising
background image

D-#S-TFK20GB

Specifications are subject to change without prior notice and any obligation on the
part of the manufacturer.
The descriptions of products shown in this document may be used by the other
companies as their trademarks.
© 2006 SMC Corporation All Rights Reserved

When you inquire about the product, please contact to followings.

URL http://www.smcworld.com

Phone

AUSTRIA / (43) 2262-62 280

ITALY / (39) 02-92711

BELGIUM / (32) 3-355 1464

NETHERLANDS / (31) 20-531 8888

CZECH REP. / (420) 5-414 24611

NORWAY / (47) 67 12 90 20

DENMARK / (45) 70 25 29 00

POLAND / (48) 22-548 50 85

FINLAND / (358) 207 513 513

PORTUGAL / (351) 2 610 89 22

FRANCE / (33) 1-64 76 1000

SPAIN / (34) 945-18 4100

GERMANY / (49) 6103 4020

SWEDEN / (46) 8-603 0700

GREECE / (30) 1- 342 6076

SWITZERLAND / (41) 52-396 3131

HUNGARY / (36) 1-371 1343

TURKEY / (90) 212 221 1512

IRELAND / (353) 1-403 9000

UNITED KINGDOM / (44) 1908-56 3888

Names and Functions of Individual Parts

Installation

Internal Circuit and Wiring

Other Functions

Outline with Dimensions

(in mm)

(M2.5

4L)

(M2.5

4L)

Indicator light

Indicator light

Sensor unit

D-M9B

AV

D-M9NA

SMC

SMC

Half strip treatment

Vinyl sheath cable

Mounting screw

Vinyl sheath cable

Mounting screw

D-M9NA / D-M9PA / D-M9BA

D-M9NAV / D-M9PAV / D-M9BAV

Actuator

Switch

Mounting screw

6.How to mount / Mounting bracket

Each actuator has a specified mounting bracket when
mounted to the autoswitch.

“How to mount/Mount bracket” depends on actuator type and

tube I.D. Please refer to the actuator catalogue.
When an auto switch is mounted for the first time, please
ensure the actuator is a magnet built-in type, then ensure
brackets correspond to the actuator.

M2.5 mount screw tightening torque shall be 0.05 to 0.15N

•m

Setting the detecting position

Set the actuator at the stroke end. Set the switch in the area to where
the auto switch red lamp lights. (Detecting actuator end)
Based on A and B dimensions in the actuator catalogue, set the switch.

D-M9NA(V)

D-M9BA(V) (Sink input mode)

D-M9BA(V) (Source input mode)

D-M9PA(V)

Brown[1]

Black[4]

Blue[3]

Brown[1]

Black[4]

Blue[3]

Brown[1]

Blue[4]

Load

Load

Brown[1]

Blue[4]

Load

Load

Power suppy

Power suppy

Power supp

Power supp

Switch main circuit

Switch main circuit

Switch main circuit

Switch main circuit

Connection with PLC (sequence controller)

2

M12-4pin connector

M8-4pin connector

M8-3pin connector

4

3

1

4

3

1

4

3

2

1

8

4.6

2

2.8

4

22

3.2

SMC

Slotted screw

Indicator light

4

2.6

9.3

D-M9NAV

Manufacturing code

Part no.(D-M9NAV

â

Most sensitive position

Manufacturing code

Indicator light

Slotted screw

Mounting screw M2.5

Ļ4

Part no.(D-M9BA)

3

0.2

24

4

2.8

D-M9BA

6

Most sensitive position

6

4

500(1000)(3000)(5000)

2.7

3.2

SMC

Mounting screw M2.5

Ļ4

500(1000)(3000)(5000)

2.7

YY

YY

D-M9NA/ D-M9PA / D-M9BA

D-M9NAV / D-M9PAV/ D-M9BAV

Problem occurs

Problem
condition

Stay OFF(sometimes ON)

Indicator light

Normal

2wires / 3wires

3wires

Wiring (output)

check

Normal

Abnormal

2wires

Load spec.check(1)

Stay OFF

Source voltage or
load voltage

Replace the Switch

Stay ON(Sometimes OFF)

Indicator light

2wires / 3wires

A

B

A

C

D

E

B

B

A

A

F

D

Load spec. check(1) ----- ON voltage > Load voltage-Internal voltage drop
Load spec. check(2) ----- OFF current > Leak current

A

B

C

D

E

F

--- Switch output parts failure(replace)

--- Check wiring and correct fault

--- Replace switch 2 wires --> 3 wires

--- Switch failure

--- Replace cylinder. Detectable magnet field in adequate (No magnet)

--- Replace PLC input board or replace switch 2 wires --> 3 wires

Normal

Abnormal

Normal Abnormal

Normal

Abnormal

Load spec.check(2)

3wires

2wires

Normal

Abnormal

Normal

Stay OFF

Stay ON

When detection failure occur(stay ON/OFF), please check based on the following flow chart.

Mark

K
L

M
N
O

P
Q

Year

2006
2007
2008
2009
2010
2011
2012

Mark

O
P
Q
R
S

T
U
V

W

X
Y
Z

Month

January

February

March

April
May

June

July

August

September

October

November
December

Manufacture’s batch marking

Year

Month

14

Connector size M12

Connector size M8

10

32.7

42.5

D-M9 A PC

A

B

D-M9 A DPC

Exterior dimension of Pre-wired connector

Advertising