Sanyo PLC-WXL46 User Manual

Page 16

Advertising
background image

PLC-WXE46/WXL46 Basic Serial Command Specifications

16/24

6.35. ON START Cancel Command

Command “C29” [CR]

Detail

Disable Power ON Start.
This status is stored in EEPROM and retained regardless of Power OFF/ON.

Response

Acceptable

[ACK] [CR]

Unacceptable “

”[CR]

6.36. Power Management Ready Command

Command “C2A” [CR]

Detail

Set Power Management to Ready mode.
This status is stored in EEPROM and retained regardless of Power ON/OFF.

Response

Acceptable

[ACK] [CR]

Unacceptable “

”[CR]

6.37. Power Management OFF Command

Command “C2B” [CR]

Detail

Set Power Management to OFF mode.
This status is stored in EEPROM and retained regardless of Power ON/OFF.

Response

Acceptable

[ACK] [CR]

Unacceptable “

”[CR]

6.38. Power Management Shut down Command

Command “C2E” [CR]

Detail

Set Power Management to Shut down mode.
This status is stored in EEPROM and retained regardless of Power OFF/ON.

Response

Acceptable

[ACK] [CR]

Unacceptable “

”[CR]

6.39. D.ZOOM + Command

Command “C30” [CR]

Detail

Enter Digital Zoom mode and expand image size.
This command works the same way as “D.ZOOM

▲” button of the remote control.

Response

Acceptable

[ACK] [CR]

Unacceptable “

”[CR]

6.40. D.ZOOM – Command

Command “C31” [CR]

Detail

Enter Digital Zoom mode and reduce image size.
This command works the same as “D.ZOOM

▼” button of the remote control.

Response

Acceptable

[ACK] [CR]

Unacceptable “

”[CR]

Advertising