MK1000 MicroKiosk Product Reference Guide

Table F-1. Troubleshooting

Problem

Possible Causes

Possible Solutions

1. MK1000 does not turn on.

No power to the device.

- Power via AC outlet

- Check AC power to the device.

Ensure power supply is plugged
into AC power source and the
MK1000.

- Power via power-over-Ethernet

- Confirm Ethernet cable is plugged

into MK1000 LAN port.

- Confirm other end of Ethernet

cable is plugged into Bias-T
(power-over-Ethernet).

- Confirm Bias-T (power-over-

Ethernet) module is plugged into
an AC outlet.

- Perform continuity check on

Ethernet cable.

2. MK1000 does not respond to

polls from the host computer
(RS-485 only).

No communication
between the host and
MK1000.

Check cabling to the MK1000. Ensure
the MK1000 address is the same as
the one you are polling.

Note: When the MK1000 has not been
polled for one minute, it displays a
default “Out of Service” message
(unless the default message was
changed).

Check polarity of signal at connection
to network.

Check communication parameters.