SECO-LARM USA Enforcer RF Receivers SK-910R-4 User Manual

Page 4

Advertising
background image

SECO-LARM

®

U.S.A., INC.

16842 Millikan Avenue
Irvine, CA 92606

Telephone
(800) 662-0800
(949) 261-2999

The SECO-LARM policy is one of continual development and improvement.

For this reason, SECO-LARM reserves the right to change specifications without further notice.

FILE: TE-10, C:\DTP\MANUAL\MUK910R2.P65 APR2001
ORDER PART# 762-091-4 (904)

General Specifications

Operating Frequency:

315 MHz (SK-910R, SK-910RL, SK-910R2)

433.92 MHz (SK-910R-4, SK-910RL-4, SK-910R2-4)

Memory Capacity:

15 transmitter button codes per channel

Operating Voltage:

11VDC ~ 24VDC or 11VAC ~ 24VAC
5VDC ~ 13VDC (SK-910RL / SK-910RL-4 only)

Operating Current:

8 mA @ 12VDC (standby)
30mA/channel @ 12VDC (activated)
70mA @ 6VDC (activated), (SK-910RL / SK-910RL-4 only)

Relay Contact Rating:

Form ‘C’ type; 10A @ 24VDC or 120VAC per channel

Connectors:

Screw Terminals, +, –,
with N/O, N/C, and COM per channel

Dimensions:

3.25” x 2.7” x 1.1” (83 x 68 x 27.5 mm)

Compatible Transmitters

COM

NC

NO

-

+

COM

NC

NO

-

+

COM

NC

NO

-

+

COM

NC

NO

-

+

Positive Power Source

Positive Power Output

Power for SK-910R

Negative Power Source

Negative Power Output

Power for SK-910R

12VDC O/P

GND

+12VDC

24VAC(1) Input

24VAC(1) Output

GND

+12VDC

}

}

315 MHz

SK-919TD1S

1-button, Fixed Code

SK-919TD2A

2-button, Fixed Code

SK-917T3A

3-button, Code Hopping

SK-917T2A

2-button, Code Hopping

433.92MHz

SK-939TS1S

1-button, Fixed Code

SK-939TS2A

2-button, Fixed Code

SK-937TS2A

2-button, Code Hopping

SK-937TS3A

3-button, Code Hopping

Typical Applications:

Positive Output:

Negative Output:

12VDC receiver power driving a 12VDC apliance:

12VDC receiver power input, 24VAC output driving a motor

}

Power for SK-910R

24VAC(2)

Motor

2

1

Fax
(949) 261-7326

Advertising