Installing the hob (continued), Connecting to the mains power supply – Samsung C61RCBAL User Manual

Page 8

Advertising
background image

6

EN

Installing the Hob (Continued)

Connecting to the mains power supply

Before connecting, check that the nominal voltage of the appliance, that is, the voltage stated on the rating

plate, corresponds to the available supply voltage. The rating plate is located on the lower casing of the

hob.

Shut off power to circuit before connecting wires to circuit.

The heating element voltage is AC230 V~. The appliance also works perfectly on older networks with

AC220 V~.
The hob is to be connected to the mains using a device that allows the appliance to be disconnected from

the mains at all poles with a contact opening width of at least 3 mm, eg. automatic line protecting cut - out,

earth leakage trips or fuse.
A type H05SS - F (180°C) cable or one of a higher grade must be used as the mains connecting cable.

Rated current of appliance (A)

Nominal cross-sectional area (mm

2

)

1N~

> 25 and ≤ 32

> 4 and < 6

2N~

> 10 and ≤ 16

> 1.5 and < 2.5

The connection must be carried out as shown in the diagram. The connecting links should be fitted accord-

ing to the appropriate connection diagram.
The earth lead is connected to terminal. The earth lead must be longer than leads carrying electric current.

The cable connections must be made in accordance with regulations and the terminal screws tightened

securely.

The connecting cable is to be secured with the mains cable cleat and the covering closed by pressing firmly

(locking into place). Before switching on for the first time, any protective foil or stickers must be removed

from the ceramic glass surface.

Once the hob is connected to the mains supply, check that all cooking zones are

ready for use by briefly switching each on in turn at the maximum setting.

When the hob is powered on for the first time, all displays light and the child safety

lock is activated.

< IN ~ >

L: Brown

N: Blue

PE: Green

Warning: Pay attention (conformity) to phase and neutral allocation of house

connection and appliance (connection schemes); otherwise, components can be

damaged.

Warranty does not cover damage resulting from improper installation.

C61RCCN_XSA-00043A_EN.indd 6

2007-02-22 ¿АИД 2:04:36

Advertising