Output terminals, Tape end out terminal, Com terminal – Sanyo SRT-8040 User Manual

Page 46: Timer out terminal

Advertising
background image

OUTPUT TERMINALS

TAPE END OUT Terminal

œ

During recording, when the end of the tape is reached
or when the tape counter reading indicates 8 hours,
the output becomes 0V (Low). During autorepeat
recording, the output becomes 0 V (Low) for about 2
seconds only.

œ

To reset the output, press the STOP or EJECT button.

TAPE END OUT Terminal Output Setting

1

Press the MENU button to display the MAIN MENU.

2

Turn the JOG dial to select the “5.ALARM/SERIES
REC SET” line, then turn the SHUTTLE ring
clockwise.

ø

The (ALARM/SERIES REC SET) menu
appears.

<ALARM/SERIES@REC@SET>

*ALARM@SET

@@MODE@@@@@@@@@@@Y1

@@SPEED@@@@@@@@@@8H

@@DURATION@@@@@@@20S

*1@SHOT@SET

@@FIELD@@@@@@@@@@1

@@INTERVAL@@@@@@@1M

*SERIES@REC@@@@@@N

*TAPE@END@OUT@@@@8:00

3

Turn the JOG dial until the “TAPE END OUT” setting
is highlighted, then turn the SHUTTLE ring clockwise.

4

Turn the JOG dial to select the desired mode, then
turn the SHUTTLE ring clockwise.

8:00 (6:00) . . The output becomes 0 V (Low)

when the tape counter reaches
“8H 00M 00S (or 6H 00M 00S)”
and/or when the tape reaches the
end.

END . . . . . . . The output becomes 0 V (Low)

when the tape reaches the end.

NOTES:

œ

If the “TAPE” in the (GENERAL SET) menu is set
to “T-120”, “6:00” will be indicated instead of
“8:00”.

œ

If the “SERIES REC” is set to “Y” in the
(ALARM/SERIES REC SET) menu, the output
becomes 0 V (Low) for about 2 seconds when the
counter reaches “8H 00M 00S”, even if the “TAPE
END OUT” is set to “END”.

œ

If the “SERIES REC” is set to “Y” in the
(ALARM/SERIES REC SET) menu, the output
becomes 0 V (Low) until 5 minutes have passed
after the tape reaches the end.

5

Press the MENU EXIT button.

COM Terminal

œ

Common GND (ground) terminal when connecting
other terminals to external devices.

TIMER OUT terminal

œ

During timer recording, the output becomes 0 V.

œ

During timer recording stand-by mode, the output is 5
V (High).

Timer recording

5V (H)

0V (L)

(Output impedance: 5.7 k

)

RF4QR/NA (SRT-8960 GB) Tue. Mar., 05/2002

English

45

Advertising
This manual is related to the following products: