3. Method of operation:

I. Hole diameter ( small / large ) :

The HL 100 can be directly installed in holes from

7

/

8

” to 3” in diameter using

the yellow locking nut (5). The large black locking nut (6) and the adapter
plate (7) are used for larger holes of 3

1

/

4

” to 4

3

/

4

” in diameter. Tighten the

locking nut until the tool is firmly in place. The conical shape centers the
HL 100 in the hole.

II. Material thickness ( min. / max. ) :

The HL 100 can be fixed in materials up to 1

1

/

2

” thick and up to 3” thick for

hole diameters larger than 1

1

/

2

”. By using the large locking nut adapter (6)

as shown below, the HL 100 can be used with materials less then 1

1

/

2

” thick,

such as TJI’s. In this case the distance from the center of the hole to the flange
to should be more than 1

1

/

2

” .

s

3.2. Working in horizontal mode

I. Installing the HL 100:

Lay out the hole location on the first joist / stud. Mark and drill required hole
size. Clean away excess wood chips and install HL 100 as described above.

s = max. 3”

3.1. Installation in joists / studs / panels

X = min. 1,5”

X