4 Alignments and Adjustments

MJ15AS*/MJ17AS*/MJ19AS*/
MJ15BS*/MJ17BS*/MJ19BS*

4-3

Figure 4.

4-6-3 How to Control Service Function OSD

After change the panel or lamp, you must reset service function OSD.

The case of panel change

After changeing the panel, press the menu key within 5 seconds,.
Then, panel Ch. No increases one step and the panel time information is reset to zero.
Simultaneously, other information is reset to zero (Upper/Lower lamp, Panel cycle).

Figure 5, 6.

4-6-4 How to Control Service Function OSD

In the case of Upper Lamp or Lower Lamp change

After changeing the Upper Lamp or Lower Lamp,

1. Select the Upper Lamp or Lower Lamp
2. Press the Menu key within an 5 seconds.

Then, Ch. No and time will be reset to zero (selected item only).