Sccg50 & sccp50 service parts, Wiring diagram, Power in – Scotsman Ice Residential Ice Machines SCC50 User Manual

Page 9

Advertising
background image

Wiring Diagram

June 2008

Page 9

SCCG50 & SCCP50 Service Parts

BIN LIGHT
SWITCH

BIN
LIGHT

W

DRAIN
PUMP
MOTOR

W

BK

R

BK

PUMP
PRESSURE
SWITCH

NO

COMM

NC

R

SAFETY
PRESSURE
SWITCH

NO

COMM

NC

W

PUMP
MOTOR

BU

W

R/W

WATER

SOLENOID

W

BN

FAN
MOTOR

R

HOT GAS

SOLENOID

GN/Y

GN/Y

Y

Y

J2

2

1

J5

2

1

GN/Y

EARTH GROUND

V

3

2

1

J1

J4

1

2

3

4

5

6

BK

W

O

TRANSFORMER

LOAD

LINE

J9

12

ELECTRONIC
CONTROL

SUCTION
TEMP.
SENSOR

WATER
CONDUCTIVITY
SENSOR

R

R

ON

OFF

BIN
LEVEL

CONTROL

3

2

J7

1

POWER IN

W

BK

GN/Y

W

W

BK

BK/W

1

3

S

M

1

OVERLOAD

RELAY - CURRENT

COMPRESSOR

IF DRAIN PUMP
IS INSTALLED