Xc-e series, Uv model xc-eu50/eu50ce, Spectral response – Sony XC-E Series User Manual

Page 2: Applicable wavelength range

Advertising
background image

XC-E Series

Applicable wavelength range

Applicable wavelength range

Standard model

XC-ES50/ES50CE
XC-ES50L/ES50LCE
XC-ES51/ES51CE
XC-ES30/ES30CE

Near IR model

XC-EI50/EI50CE
XC-EI30/EI30CE

Accessories

400-770 nm

400-770 nm

300

400

700

800

900

300

400

700

800

900

UV model
XC-EU50/EU50CE

300-420 nm

300

400

700

800

900

Applicable wavelength range

Spectral response

300

400

100%

90%

80%

70%

60%

50%

40%

30%

20%

10%

0%

500

600

700

800

900

1000

Wavelength (nm)

XC-ES/ST Series

XC-EI Series

XC-EU Series

Standard CCD with IR Cut Filters

Note following differences between models:

• XC-EI models are more sensitive than XC-ES models, not only in near-IR range but in visible range as well.

• XC-ES51/ES51CE has an improved sensitivity over XC-ES50/ES50CE.

• XC-EU models are only sensitive in near-UV range and are not susceptable to disturbance from surrounding

visible light.

• XC-ES50L/ES50LCE include an IR Cut Filter.

Compact camera adaptor
DC-700/700CE
• Compact, lightweight (700 g, 1 lb 8 oz)
• External sync IN/OUT
• Trigger input / WEN output
• New EIAJ standard 12 pin connector
• Dimensions: 110 (W) x 53 (H) x 160 (D) mm

(4

3⁄ 8

x 2

1⁄2

x 6

3⁄ 8

inches)

12 pin camera cable (CE standard)
• CCXC-12P02N (2 m)
• CCXC-12P05N (5 m)
• CCXC-12P10N (10 m)
• CCXC-12P25N (25 m)

Tripod adaptor
VCT-333I
• ABS
• Approx. 6.1 g (0.2 oz)
• Dimensions: 18 (W) x 6 (H) x 27 (D) mm

(2

2⁄ 32

x

1⁄ 4

x

1⁄ 8

inches)

The XC-EU50/EU50CE models are compact and light-weight
cameras that have near-ultraviolet sensitivity in the i-line, or 365 nm,
range. Examples of typical application areas are PCB and solder
inspection, document proofing, microscopy, medical and
cosmetics applications. Using UV lighting, the short wavelength
allows the XC-EU50/EU50CE models to capture clearly very fine
detail and surface structures, which cannot be detected using
visible or IR lighting, including very small scratches, dust or
blemishes, as well as special fluorescent materials.