Samsung SYNCMASTER 320MPN-3 User Manual

Page 35

Advertising
background image

Header

com-

mand

ID

DATA

Length Ack/Nak r-CMD

Val1

Check

Sum

0xAA

0xFF

3

‘A’

0x3D

Auto Ad-

justment

• Nak

Header

com-

mand

ID

DATA

Length Ack/Nak r-CMD

Val1

Check

Sum

0xAA

0xFF

3

‘N’

0x3D

ERR

ERR : Error code that shows what occurred error is

• Video Wall Mode Control

• Function

Personal Computer converts Video Wall Mode of TV / Monitor when Video Wall is ON.

Only works with TV / Monitor where Video Wall is on.

Does not operate in MagicInfo

• Get Video Wall Mode

Header

command

ID

DATA Length

CheckSum

0xAA

0x5C

0

• Set Video Wall Mode

Header

command

ID

DATA

Length

DATA

CheckSum

0xAA

0x5C

1

Video Wall

Mode

Video Wall Mode : Video Wall Mode code to be set on TV / Monitor

1 : Full

0 : Natural

• Ack

Header

com-

mand

ID

DATA

Length Ack/Nak r-CMD

Val1

Check

Sum

0xAA

0xFF

3

‘A’

0x5C

Video

Wall

Mode

Video Wall Mode : same as above