Function and Location of Parts and Controls

7

made with the GAIN control section and SHUTTER
setting section are ignored.

l CHARACTER button
Press this button (which lights up when pressed) to
display the self-diagnostics screen on the picture
monitor. Each time you press this button, the screen

changes to the next page. When this button is not lit, the
self-diagnostics screens are not displayed.

m MASTER GAMMA adjustment knob
Use this knob to adjust the gamma curve.

n DETAIL adjustment knob
Use this knob to adjust the detail level.

o SHUTTER setting section
Selects a shutter setting.

Note

This section does not function when the TLCS button is
on.
CLS button
Press this button (which lights up when pressed) to
activate the clear scan function.
ON button
Press this button (which lights up when pressed) to
activate the normal shutter function.
UP/DOWN selector
When the CLS button lights:
The clear scan frequency
is increased, each time you press this selector to the UP
position. The clear scan frequency is reduced, each time
you press this selector to the DOWN position.
When the ON button lights: The shutter speed is
increased, each time this selector to the UP position. The
shutter speed is reduced, each time you press this
selector to the DOWN position.

Display
Displays the clear scan frequency when the CLS button
lights, or the shutter speed when the ON button lights.

p GAIN control section
Adjusts the gain to obtain the most appropriate level for
the lighting condition.
UP/DOWN selector
The gain is increased, each time you press this selector
to the UP position. The gain is decreased, each time you
press this selector to the DOWN position.
Display
Displays the gain values in decibel units.

q WHITE/BLACK BALANCE setting section

r MASTER BLACK

adjustment knob

s IRIS setting section

o SHUTTER setting section

p GAIN control section