TRoubLeSHooTING (cont’d)

SYMPTOM 1. Toilet will not flush and water will not enter toilet bowl.

Condition
Mode Switch in SERVICE position.
Valve Open Limit Switch problem.

Valve Closed Limit Switch problem.

Insufficient vacuum in system.

Flush valve motor relay failure.

Corrective Action
Return Mode Switch to NORMAL position.
With the flush valve fully open, check the “VALVE OPEN” status light. If

the light is

off, then the Valve Open Limit Switch is out of alignment or

defective, or related wiring is defective.
With flush valve in the fully closed position check the “VALVE CLOSED”

status light. If the light is

off, then the Valve Closed Limit Switch is out

of alignment or defective, or related wiring is defective.
Check the “HI VAC” status light. If the light is

off, the signal from the vac-

uum switch located on the vacuum generator or vacuum tank is absent

and preventing the toilet from flushing in the NORMAL mode. Check

for loss of power to the vacuum generator or vacuum pump. Check for

loose or defective wiring between the vacuum switch and the toilet.
Replace control module.

eRRoR CoDe CoRReCTIve pRoCeDuReS

ToILeT opeRATIoN

Condition
+5V status light is

off (on far

right of control module):

+5V status light is

on:

Corrective Action
• Check toilet fuse or circuit breaker at DC distribution panel.
• Check for loose or defective wiring between control module and DC

distribution panel.

• Check for reverse polarity of input power to control module.
• If all of above check OK, replace control module.
• Input power must be 10 volts or higher.
• Check control module for error codes.
• Check “HI VAC” status light. If light is

off, vacuum is low, preventing

the toilet from flushing.

• Check “HOLD TANK FULL” status light. If light is

on, black water

holding tank is full, preventing toilet from flushing.

• Put Mode Switch in SERVICE position. If flush valve

opens, go to

next step. If the flush valve

does not open, go to Symptom 2.

• Put the Mode Switch in NORMAL position and push flush handle

down while observing “FLUSH” status light. The “FLUSH” status

light must come

on when the handle is pressed and go off when the

handle is released. If the “FLUSH” status light

did not follow com-

mands of handle, then flush switch or related wiring is defective.

SYmpTom 2. Flush valve will not open when the mode Switch is in the SeRvICe position or when

the flush handle is pushed while in the NORMAL position.

Procedure
Check the voltage output

to the flush valve motor at

jack 6, pins 9 and 10 on the

control module as follows:

Corrective Action
• Pull the control module out as far as the control cables will allow.

Locate jack 6 at the bottom of the control module.

• Remove the purple wire from pin 6.
• With DC voltmeter test leads across pins 9 and 10, flip the Mode

Switch between the NORMAL and SERVICE positions. If voltage is

present for about two seconds in the SERVICE position, the flush

valve motor or related wiring is defective. If voltage is not present,

replace the control module.