FLuSH meCHANISm CompoNeNTS

. To access

base assembly

c o m p o n e n t s ,

remove decora-

tive screw caps

and unscrew the

bolts that hold

china toilet to

floor.

2. Remove access cover.

Lift up control module. Dis-

connect power cable and

vacuum control cable from

control module.

Do not

disconnect flush handle

cable or base assembly

cable.

3. Lift china toilet

straight up and set it

down close to front of

floor flange/adapter

assembly. Turn off

water to toilet and

disconnect flexible

water line at rear of

base assembly. The

toilet is completely

disconnected.

mode

Switch

Water

Level Switch

power

Cable

CoNTRoL moDuLe

Input for

base Assembly

Cable

Input

for

Flush

Switch

Cable

Input

for

vacuum

Control

Cable

Flush

Switch

Flush

Handle

Cable

Flush

Handle

base Assembly

Cable

bASe ASSembLY CompoNeNTS

(under china toilet)

Water valve

Flush ball

Closed Limit

Switch

motor

Drive Arm

Rotor Arm

Flush valve

motor

Flexible Water Supply Hose

open Limit

Switch

Discharge Adapter

(3048, 3148, 3348,

3448)

FLuSH HANDLe

(3000, 3300 toilets)

(under Access Cover)

RemoTe FLuSH SWITCHeS

(3100, 3400 toilets)

Vimar switch - marine

Gewiss switch - marine

RV flush switch

Discharge Adapter

(

3006, 3009, 3106, 3109,

3309, 3409)

Advertising