Schneider Electric Communication Drivers User Manual

Page 49

Advertising
background image

TSX FPC 10 ISA card

49

Advanced
configuration

To access the advanced configuration screen use the commands
"File->Advanced Configuration"
.
The following window is displayed:

The following table describes the different areas and buttons in the window.

Zone

Description

I/O address

Used to choose the address in the storage area with which the driver
can find the Fipway FPC10 module. This address must be included

between 100h and 3F0h and be identical to the address configured in

the module.

DMA channel

Used to select the DMA resource shared by the driver and the module.

This information must be identical to that configured on the module.

Interrupt

Used to select the interrupt shared by the driver and the communication
module. This information must be identical to that configured on the

module.

Mode

Used to disable the driver by checking the "OFF" box. This is usually the
case for the second instance of the driver. (FIP02).

WorldFip

Allows use of frames in WorldFip profile A format whose CRC

calculation complies with the IECSC65C105 standard.

Cancel button

Used to return to the previous window.

By default button

Used to configure the different areas with default parameters.

OK button

Used to acknowledge the new configuration parameters.

OK

Cancel

By default

PRUC

Configuration FIP FPC SN - Advanced

I/O address

210h

DMA channel

World FIP

Channel 5

Channel 6

Channel 7

Interrupt

IRQ 10

IRQ 11

IRQ 15

IRQ 3

IRQ 5

Mode

On

Off

0