27

EF3801/4001 T-1/T-2 Sensor

Replacement Instruction

OVERVIEW

First production 2005 stoves Serial #3384 to #3420 require precautionary replacem ent of both T-1 and T-2 sensors. The
sensors located in the stove body sense the operating tem peratures and overall param eters of the stove. The T-1 sensor
provides blocked flue and operating sensing while the T-2 sensor provides start up, shut down, and over tem p. sensing.
The first 26 units have a sensor assem bly attached in such a way that m ay cause the stove to act erratically. As a
precaution we are requiring replacem ent of the sensors and offering a repair credit. Please contact custom er service @
800-527-4790x29 for further inform ation.

T-1 and T-2 Sensor Replacem ent:

Removal from 3801 and 4001 Insert: The T-1 and T-2 sensors m aybe accessed by rem oving the inspection covers on
back of the unit. The T-1 sensor is installed into to the right side of the com bustion housing just above the exhaust tube.
Unplug the harness connector to the sensor. Using a wrench, unscrew the brass fitting and sensor holder from the
exhaust pipe. The T-2 sensor is located right of the com bustion housing attached on the lower portion of the m anifold.
Unplug the harness connector the sensor. Rem ove the #10 nut attaching the sensor holder and rem ove the sensor.
Reverse process to install new sensor fitting and holder. Reinstall the rear panel and confirm standard operation.