Stoelting F431 User Manual

Page 16

Advertising
background image

6

2. Connect free end of tubing to mix check valve.

Observe direction of check valve flow arrow.
Secure with hose clamp. Connect 24 inch (61cm)
length of 3/8 inch (9,5mm) I.D. plastic food grade
tubing to free end of check valve and secure with
hose clamp.

3. Connect elbow fitting to free end of tubing. Con-

nect opposite end of elbow to 1/4 inch I.D. tan
tubing on the left side of pump head. Secure with
hose clamps (see Figure 5 and 6).

When Using Bag Connection System (BCS) with
Two Bags Per Side (optional kit #2183189):

1. Connect 3/8 inch (9,5mm) I.D. plastic food grade

tubing to a bag adapter. Secure with hose clamps.
This bag adapter will connect to the bag nearest
the front of the freezer.

2. Slide the hose clip over free end of 3/8 inch

(9,5mm) I.D. plastic food grade tubing. Attach
free end of tubing to a manifold adapter. Secure
with large hose clamp or equivalent. Push the
manifold adapter into the left port of the mix inlet
manifold and secure with retaining clip. (see
Figure 9).

3. Connect 3/8 inch (9,5mm) I.D. plastic food grade

tubing to a bag adapter. Secure with hose clamps.
This bag adapter will connect to the bag nearest
the back of the freezer.

4. Attach free end of tubing to a manifold adapter.

Secure with large hose clamp or equivalent. Push
the manifold adapter into the right port of the mix
inlet manifold and secure with retaining clip. (see
Figure 9).

5. Place two mix bags into each mix container as

shown in Figure 10 (left mix container shows two
bag configuration).

6. Connect the bag adapter attached to the left side

of the manifold to the mix bag in the front of the mix
container (nearest the cabinet door). Connect the
bag adapter attached to the right side of the
manifold to the mix bag in the back of the mix
container (see Figure 10).

When Using Bag Connection System (BCS) with
One Bag Per Side (optional kit):

1. Connect 3/8 inch (9,5mm) I.D. plastic food grade

tubing to a bag adapter. Secure with hose clamps.

2. Connect free end of 3/8 inch (9,5mm) I.D. plastic

food grade tubing to mix check valve. Observe
direction of check valve flow arrow. Secure with
hose clamp. Connect 3/8 inch (9,5mm) I.D. plas-
tic food grade tubing to free end of check valve and
secure with hose clamp.

3. Connect elbow fitting to free end of tubing. Con-

nect opposite end of elbow to 1/4 inch I.D. tan
tubing on the left side of pump head. Secure with
hose clamps (see Figure 5 and 6).

4. Place one mix bag into each mix container as

shown in Figure 10 (right mix container shows one
bag configuration).

5. Connect the bag adapter to the mix bag. (see

Figure 10).

When Using Two Mix Containers or Bag
Connection Systems (BCS) on one Side
(optional kit #2183189):
1. The F431 can be configured to operate with only

one freezing cylinder turned on. This may be done
if only one flavor is being dispensed during slow
times. In this case, running only one freezing
cylinder will help minimize product breakdown,
while reducing mix container filling or mix bag
replacement.

2. Connect two mix containers or two mix bags as

described above, but connect both containers to
the mix line manifold of the freezing cylinder you
will be using.