Alignment and adjustments – Samsung DV438. User Manual

Page 2

Advertising
background image

2

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer

before servicing, unless testing requires power.

ALIGNMENT AND ADJUSTMENTS

An occurrence of an Error will make a sound of error melody for 5sec and con

tinuously show one of the Error Displays from the following errors.

Error Display

Trigger

Action Taken

LED

LCD

tS

The Thermistor

resistance is very low or

high.

Check for :

- Clogged lint screen

- Restricted vent system.

- Check Thermistor resistance.

tO

dO

Running the dryer with

door open

Check for :

- Close the door, and run the

dryer

- Loose or open wire terminals

in Door sense circuit.

dF

Invalid state for more

than 256 milliseconds

Check for :

- Loose or open wire terminals

in Door

sense circuit.

bE

Invalid state of key

circuit short for 75secs

Check for :

- Display PCB key circuit short

or not

od

Invalid Dry time in

excess Dry time

Check for :

- Sensor bar Open

- Using Adjust time Up exces-

sively

hE

Invalid heating Temp in

running the dryer

Check for :

- Restricted vent system.

- Check Thermistor resistance.

Et

Invalid state of Eeprom

communication

Check for :

- PCB on Eeprom circuit

FE

Invalid power source

Frequency

Check for :

- Not using regular power

source frequency

- Invalid power frequency sense

circuit

ERROR ITEMS AND DIAGNOSTIC CODES