APPENDIX
■ DIP-SW 2
Switch
Function
ON
OFF
2-1
Character code table
See table below.
2-2
2-3
(Not used)
2-4
Setting the paper width
3.25-inch,
2.25-inch
3.0-inch
2-5
(Not used)
2-6
2-7
International character set
See table below.
2-8
■
■
Character code table (switches 2-1, 2-2)
Switch
U.S.A. & Europe
IBM #1
IBM #2
Japan
2-1
ON
OFF
ON
OFF
2-2
ON
ON
OFF
OFF
■
■
International character set (Switches 2-6, 2-7 and 2-8)
Switch
U.S.A.
France Germany England Denmark Sweden
Italy
Spain
2-6
ON
OFF
ON
OFF
ON
OFF
ON
OFF
2-7
ON
ON
OFF
OFF
ON
ON
OFF
OFF
2-8
ON
ON
ON
ON
OFF
OFF
OFF
OFF
■ DIP-SW 3 (For serial interface type only)
Switch
Function
ON
OFF
3-1
3-2
Data transmission rate
See next page
3-3
3-4
Auto cutting
Invalid
Valid
control mode *3 (SP342)
3-5
Data composition
DTR mode
X-ON/X-OFF mode
3-6
Data word length
8-data bit
7-data bit
3-7
Vertical parity check
No parity check
Parity check
3-8
Parity
Odd parity
Even parity
*3 When a command is given to continuously feed paper over 7/6 inches in the