1. All wiring must comply with local and national
electrical codes and must be installed by a
licenced electrician. If you have any questions
regarding the following instructions, contact a
licenced electrician.

2. Check available power supply and resolve any
wiring problems BEFORE installing and operating
this unit.

3. For your safety and protection, this unit is
grounded through the power cord when
plugged into a matching wall outlet. If you are
not sure whether your wall outlet is properly
grounded, please consult a licenced
electrician
.

4. The wall outlet (3-pin) must match the plug
(3-pin) on the power cord supplied with the unit.
DO NOT use plug adapters or extension cords.
See (Table 1) for receptacle and fuse information.

5. The rating plate on the unit contains electrical
and other technical data. The rating plate is
located on the right side of the unit. Make sure
to use the correct power supply according to the
rating plate of your air conditioner.

Table 1

If the air conditioner has a serial plate rating
of 115 volts and up to and including 7.5 amps,
the unit maybe on a fuse or circuit breaker
with other devices. However, the maximum
amps on all devices for that fuse or circuit
breaker can not exceed the amps of the fuse
for the circuit breaker.

If the air conditioner has a serial plate rating
of 115 volts and greater than 7.5 amps it
must have its own fuse or circuit breaker,
and no other device or unit should be
operated on the fuse or circuit breaker.

If the air conditioner has a serial plate rating
of 230 volts, it must have its own fuse or
circuit breaker, and no other device or unit
should be operated on the fuse or circuit
breaker.

To avoid the possibility of personal injury,
disconnect power to the unit before installing
or servicing.

Electric Shock Hazard

Electrical specifications

!

125

10K-12K
(Cooling only)

24K
(Cooling only)

15

15

RATED VOLTS

COOLING CAPACITY

250

AMPS

FUSE SIZE

WALL OUTLET

20

20

RECEPTACLE AND FUSE TYPES

18K(Cooling only)
10K-12K(With heating)

15

30

30

15

250

250

18K-24K
(With heating)