StorageTek L700 User Manual

Page 44

Advertising
background image

Specifications

A-2

First Edition

96047

Table A-3. Physical Specifications

Specification

L180

L700

Height

8.9 cm (3.5 in.)

13.3 cm (5.25 in.)

Width

48.3 cm (19 in.)

48.3 cm (19 in.)

Depth

45.7 cm (18 in.)

63.5 cm (25 in.)

Weight

28.6 kg (63 lb)

51.8 kg (114 lb)

Rack space (units)

2 U

3 U

Table A-4. Environmental Specifications

Temperature:
Operating
Storage

0º to 40ºC (32º to 104ºF)
-15º to 45ºC (50º to 113ºF)

Altitude:
Operating
Storage

0 to 3.05 km (0 to 10,000 ft)
0 to 15.24 km (0 to 50,000 ft)

Relative humidity (operating and storage) 0 to 95% (non-condensing)

Table A-5. UPS Typical Runtime

Load (Watts)

Volt Ampere

L180

L700

65

100

4 hr 10 min.

5 hr 52 min.

130

200

2 hr 16 min.

3 hr 31 min.

195

300

1 hr 28 min.

2 hr 27 min.

260

400

1 hr 3 min.

1 hr 50 min.

325

500

47 min.

1 hr 26 min.

390

600

36 min.

1 hr 10 min.

455

700

28 min.

58 min.

520

800

23 min.

44 min.

585

900

18 min.

41 min.

650

1000

15 min.

36 min.

780

1200

11 min.

26 min.

910

1400

8 min.

21 min.

1040

1600

16 min.

1300

2000

10 min.

1430

2200

9 min.

1625

2500

5 min.

Advertising