Sharp PN-465E User Manual

Page 26

Advertising
background image

24

E

Initialisation (Reset)/Functional Restriction Setting

You can return the settings to their factory-preset values and

restrict operations.

1. After pressing

SIZE

for about 5 seconds, press

,

,

, and

in that order.

OFF

ON
ON

UNLOCKED

FUNCTION

1/1

ALL RESET

ADJUSTMENT LOCK
OSD DISPLAY
LED
RS-232C

END…[MENU]

2. Select and set the items.

ALL RESET
Resets the settings to the factory default settings.
Press

, select “ON” and then press

MENU

.

After initialisation, turn the main power switch off and

then back on.
ADJUSTMENT LOCK
You can disable operations on the monitor and the

remote control unit that use buttons.

OFF ...Enables operation.

1 ........Disables all operations other than turning power

on/off and FUNCTION.

2 ........Only the FUNCTION operation is enabled.

Disables all operations other than FUNCTION (not

even power on/off).

OSD DISPLAY
Hides/shows menus.

The FUNCTION screen cannot be hidden.

ON ...........Displays the menus.

OFF .........Hides the menus.
LED
Specifies whether to light power LEDs.

ON ...........Lights power LEDs.

OFF .........Does not light power LEDs.
RS-232C
Specifies whether to allow control via RS-232C (see

page 25).

LOCKED .............Disables control via RS-232C.

UNLOCKED........Enables control via RS-232C.

3. Press

MENU

to return to the normal screen.

Advertising