Simple Connection to MKS-8080/8082 AUX Bus Remote Panel

Simple Connection to
MKS-8080/8082 AUX Bus
Remote Panel

You can connect the MKS-8080/8082 AUX Bus Remote
Panel to enable remote control of the switcher’s AUX
buses.
To connect the MKS-8080/8082 to the control panel
requires an HKSP-R80 Routing Switcher Controller Board
or similar device constituting a primary station for an S-
Bus data link, as well as various settings for connction.
However, using a simple connection, the need for an S-Bus
data link primary station is avoided, and direct connection
to the MKS-8080/8082 is possible.
A simple connection is possible if the following conditions
are met:
• There are no devices other than the MFS-2000 and

MKS-8080/8082 connected on the S-Bus data link.

• There are no more than 16 MKS-8080/8082 units

connected on the S-Bus data link.

For settings on the MKS-8080/8082, refer to “Making the
Settings With Buttons (Setup Function)” in the MKS-8080/
8082 Operation Manual.

Proceed as follows.

1

Carry out initialization of the MKS-8080/8082
settings. (This can be done on the MKS-8080/8082
separately.)

2

Set the MKS-8080/8082 station number in the range 2
to 17. (This can be done on the MKS-8080/8082
separately.)

3

Set the STATION ID switches S108 on the front panel
of the FP-141 board to 001 (1 only is set to the OFF
side).

This sets the MFS-2000 control panel as the S-Bus
data link primary station.

4

Use the Setup/Diag >System >Initialize menu (see
page 165)
to rebo
ot the system.

When the reboot finishes, connection to the MKS-
8080/8082 is possible.

5

In the Setup/Diag >System Tally >S-Bus Assign menu
(see page 182), set the position of the MFS-2000
system in the S-Bus space as follows.

• Matrix size: Standard 136

× 138

• Source, Destination, Level: 1

The MKS-8080/8082 operates in AUX bus mode, with
settings set to the following factory defaults.

C: SET SWITCHER ID (for AUX mode)

This is set to 001, which is the station number of
the MFS-2000 control panel.

D: SET AUX DESTINATION/SOURCE (for AUX

mode)

The source is set to IN001 and following, and

destination is set to OUT001 and following.

H: SET PHANTOM TABLE (for Router mode)
This is unset, since the unit does not operate in router

mode.

N: SET PANEL TABLE (for Router mode)
The source is set to IN001 and following, and

destination is set to OUT001 and following.
However, since the unit does not operate in router
mode, these settings are not used.

R: SET ROUTE
Since when using the simple connection the switcher

and router cannot be connected in cascade, no
route setting is required, and this is unset.

O: SET AVAILABLE SOURCE/DESTINATION
The source and destination ranges are set so that the

MFS-2000 inputs and outputs can be selected.

Y: SET DISPLAY MODES
The DISPLAY MODES/PANEL FUNCTION setting

is set to NORMAL. The TALLY GROUP settings
are all set to OFF.

Z: SET PANEL STATUS
The various settings are the same as the factory default

settings.

Refer to “Menu Operations” in the Operation Manual of
the MKS-8080/8082 for the meaning of the above settings.