18 If necessary, disconnect the cable to the lower

oxygen sensor and remove the frost plug using
tool 260 147 020. Use, for example, a 17 mm
socket.

19 Apply acid-free petroleum jelly, part no. 30 06

665, or equivalent, to the heating element O-
ring.

20 Fit the heating element so that the electrical

connection is directed towards the left-hand side
of the car and the connection is between the
coolant pipes and under the turbocharger cool-
ant pipe. Do not tighten the nut holding the heat-
ing element.

21 Adjust the position of the heating element so

that it is free from contact with the coolant pipes.
Tighten the nut.

Tightening torque 3.5 Nm (2.5 lbf ft)

Connect and secure the cable to the lower oxy-
gen sensor.

22 Apply acid-free petroleum jelly, part no. 30 15

286 or equivalent, to the O-ring on the supply
connector cable and connect the cable to the
heating element.

23 Fit the lock clip over the connection. A click

should be heard when the lock clip is fitted cor-
rectly.

24 Aut: Secure the supply connector cable to the

lower cable by the battery tray with the clips
included in the kit.

Man: Secure the supply connector cable to the
left-hand structural member with a strap.