Datasheet – SMSC USB2502 User Manual

Page 21

Advertising
background image

2-Port USB 2.0 Hub Controller

Datasheet

SMSC USB2502

21

Revision 2.3 (08-27-07)

DATASHEET

5.2.3.3

EEPROM Offset 5:4(h) - Device ID

5.2.3.4

EEPROM Offset 6(h) - CONFIG_BYTE_1

5.2.3.5

EEPROM Offset 7(h) - CONFIG_BYTE_2

BIT

NUMBER

BIT NAME

DESCRIPTION

15:8

DID_MSB

Most Significant Byte of the Device ID.

7:0

DID_LSB

Least Significant Byte of the Device ID.

BIT

NUMBER

BIT NAME

DESCRIPTION

7

SELF_BUS_PWR

Self or Bus Power: Selects between Self- and Bus-Powered operation.

0 = Bus-Powered operation. (BUS Default)
1 = Self-Powered operation. (SELF Default)

Note: If Dynamic Power Switching is enabled, this bit is ignored and the
SELF_PWR pin is used to determine if the hub is operating from self or bus
power.

6

Reserved

Reserved

5

HS_DISABLE

High Speed Disable: Disables the capability to attach as either a High/Full-
speed device, and forces attachment as Full-speed only i.e. (no High-Speed
support).

0 = High-/Full-Speed. (Default)
1 = Full-Speed-Only (High-Speed disabled!)

4

Reserved

Reserved

3

EOP_DISABLE

EOP Disable: Disables EOP generation at EOF1 when no downstream
directed traffic is in progress.

0 = EOP generation at EOF1 is enabled.
1 = EOP generation at EOF1 is disabled, (normal operation). (Default)

2:1

CURRENT_SNS

Over Current Sense: Indicates whether current sensing is ganged.

00 = Ganged sensing (all ports together). (Default for self-power)
01 = Reserved
1x = Over current sensing not supported. (may be used with Bus-Powered
configurations only!, and is the default for bus-power)

0

Reserved

Reserved

BIT

NUMBER

BIT NAME

DESCRIPTION

7

DYNAMIC

Dynamic Power Enable: Controls the ability for the Hub to transition to Bus-
Powered operation if the local power source is removed (can revert back to
Self-Power if local power source is restored).

0 = No Dynamic auto-switching.
1 = Dynamic Auto-switching capable.(Default)

6

Reserved

Reserved