Final operations, 2 adjusting the minimum for bottled gas, Fitting the rear splash-back – Smeg CS122-6 User Manual

Page 9: Instructions for the installer

Advertising
background image

Instructions for the Installer

51

4. FINAL OPERATIONS

After changing the nozzles, put the pan stands, the burner caps and
flame diffuser rings back in place.

After adjusting for use of a gas other than the gas used for testing the

appliance, replace the gas setting label on the appliance with the label

for the new gas. The label is supplied in the bag with the nozzles.

4.1 Adjusting the minimum setting for town gas and natural

gas

Light the burner and turn it to the minimum
setting Remove the gas tap knob and adjust the
regulator screw inside or beside the tap rod
(depending on the model) until an even minimum
flame is obtained. Put the knob back in place and
check the stability of the burner flame (the flame
must not go out when the knob is turned quickly
from the maximum to the minimum setting). Repeat
the operation on all the gas taps.

4.2

4.3

Adjusting the minimum for bottled gas

To adjust the minimum level when using bottled gas, the adjuster screw
inside or beside the tap rod must be turned fully clockwise (depending on
the models).
The diameters of the bypasses for each individual burner are stated in
point "3.2 Burner and Nozzle Data Tables".

Fitting the rear splash-back

Place the splash-back on the hob, aligning the holes A with the holes
B.

Fix the splash-back to the hob by tightening the screws C.

Advertising