LAN Card Installation Guide

The following tables explain the relevant options available via the LCD screen in Interfaces Mode.











































Menu screen

What the options mean

Is the menu selection screen for the Host Interface option of the INTERFACES mode.

There are only two options relative to the serial interface, ignore all others.

Auto Switching - the printer automatically switches to the relative interface type and moves

into the applicable menus.

Ethernet - factory default. Allows the operator to select the interface and the relative menus

will follow.

Is the menu selection screen for the Ethernet Port option of the INTERFACES mode.

Is a menu subset of the Ethernet Port option. Will move into the Timeout menu.

This is the value used by the printer to time out from the current port and check the other selected
Port Types for data print. When the printer has not received data from the host after a certain
period of time, it must timeout in order to service other ports.

The factory default of 10 seconds with an allowable range of 1 to 60 seconds.

Determines when other ports are active and able to communicate with the printer when the
Ethernet interface is not in use.

Data Timeout - factory default. The other ports (Parallel, Serial, USB) are able to send data

to the printer when the timeout setting has been reached. This setting is adjustable via the
display menu item Timeout.

Session Close - the other ports (Parallel, Serial, USB) are able to send data to the printer

when the port has been closed. Example: If a RAW port of 9100 is open, the printer will not
accept data from another interface until that port is closed by the host.

Is the menu selection screen for the Ethernet Setting option of the INTERFACES mode.

Is a transitional screen that allows entry into the Net BIOS Protocol menu.

Allows determination of if the NIC will recognize the NetBIOS protocol.

Enable - factory default. Will recognize.

Disable - will not recognize.

This options allows for the port number to be set for ASCII print jobs. The data port number must
match the host computer setting.

The allowable range is 0 to 65535, and the factory default is 9100.

INTERFACES

Host Interface*

Host Interface

Auto Switching*

INTERFACES

ETHERNET PORT

ETHERNET PORT

Timeout

Timeout

10 sec*

Switch Out On

Data Timeout*

INTERFACES

ETHERNET SETTING

ETHERNET SETTING

NetBIOS Protocol

NetBIOS Protocol

Enable*

ASCII Data Port

1024*