UNIT INSTALLATION

Route the power supply cord so that it does not touch

any of the exterior com ponents of the heater.

1.

W hen exiting through the wall with your type L Pellet
vent pipe, you m ay go straight out through a wall
thim ble. You m ust connect a pellet vent tee at this
point and extend the vent pipe at least 3' (three feet)
vertically outside to provide good draft and allow the
gases to exit. The tee m ust have a clean out cap for
inspection and regular cleaning (Figure 4). Horizontal
runs m ust be lim ited to 2' (two feet). A wall band is
required for every 4' (four feet) m inim um on a vertical
run at an exterior wall.

2.

All pellet vent pipe connections including exit at the
rear of the heater should be sealed with high
tem perature silicone (450E) or m etallic duct tape. This
prevents sm oke and soot leakage into the living area.
If this is not done, there is a possibility that the room
fan will pick up any leakage and blow it into the room .

AUTOLITE INSTALLATION INSTRUCTIONS

The AutoLite System is factory installed with the only
installation requirem ents being the optional therm ostat.

Wall Thermostat Installation:

The wall therm ostat is designed to autom atically regulate
the room tem perature from the control panel heat setting
to the “Off” setting based upon room tem perature.
Rem em ber to leave the control panel on the "Medium or
High" position when utilizing the wall therm ostat feature.

The following is a step by step procedure for installing the
optional wall therm ostat. Note connection term inals on left
side of unit at rear (Figure 7,8). Use 18/2 therm ostat wire
for the installation.

a. Unplug heater from wall outlet and 12VDC power!

b. Rem ove factory jum p wire and hook up therm ostat

wires to term inals (Figure 7,8).

c. Locate therm ostat approxim ately 10 to 12 feet from

heater or in area that requires steady tem perature.

d. Run therm ostat wires from heater to therm ostat

along wall or under carpet etc. and hook wires to
therm ostat term inals. On new construction you
can, of course, run wire in the walls before sheet
rock or paneling is done.

e. Reconnect AC power.

f. Make sure all wiring is com pleted before plugging

the EASYFIRE Heater back into the wall outlet.

IM PORTANT - Any electrical work perform ed on the
EASYFIRE Heater should be done by qualified personnel.

Remote Control Thermostat Installation:

The rem ote therm ostat is designed to autom atically
regulate the room tem perature from the control panel heat
setting to the “Off” setting based upon room tem perature
and placem ent of the rem ote therm ostat. Rem em ber to
leave the control panel on the "Medium or High" position
when utilizing the wall therm ostat feature.

The following is a step by step procedure for installing the
optional rem ote therm ostat. Note connection term inals on
rear of unit (Figure 1,2).

a. Unplug heater from wall outlet and 12VDC power!

b. Mount m illivolt style rem ote receiver box to rear of

stove using double-sided tape.

b. Rem ove factory jum p wire and hook up therm ostat

wires to term inals (Figure 7,8).

d. Reconnect AC power and follow instructions with

rem ote therm ostat regarding set up.

IM PORTANT - Any electrical work perform ed on the
EASYFIRE Heater should be done by qualified personnel.

DOOR HANDLE ASSEMBLY

The door handle and latch m ust be assem bled and adjusted
prior to the operation of the stove.

1.

Position handle assem bly through door and secure with
collar by sliding over shaft and tightening with allen
wrench provided (Figure 9).

2.

Position latch on end of shaft with flat facing allen screw.
Depending on gasket, shaft will protrude approx. 1/4"
through back of latch collar. Snug allen screw.