start up condItIons

sMoKe/odor
It is not uncommon to experience a small amount of smoke and odor

during the initial start-up. This is due to burning off of oil from metal

parts, and will disappear in a short while.
therMal eXpansIon

As water is heated, it expands (thermal expansion). In a closed

system the volume of water will grow when it is heated. As the

volume of water grows there will be a corresponding increase in

water pressure due to thermal expansion. Thermal expansion can

cause premature tank failure (leakage). This type of failure is not

covered under the limited warranty. Thermal expansion can also

cause intermittent Temperature-Pressure Relief Valve operation:

water discharged from the valve due to excessive pressure build

up. This condition is not covered under the limited warranty. The

Temperature-Pressure Relief Valve is not intended for the constant

relief of thermal expansion.
A properly sized thermal expansion tank must be installed on all

closed systems to control the harmful effects of thermal expansion.

Contact a local plumbing service agency to have a thermal

expansion tank installed.

operatIonal condItIons

sMellY water
In each water heater there is installed at least one anode rod (see

Figure 1) for corrosion protection of the tank. Certain water conditions

will cause a reaction between this rod and the water. The most

common complaint associated with the anode rod is one of a “rotten

egg smell” in the hot water. The smell is a result of four factors which

must all be present for the odor to develop:

a. A concentration of sulfate in the supply water.
b. Little or no dissolved oxygen in the water.
c. A sulfate reducing bacteria which has accumulated within the

water heater (this harmless bacteria is nontoxic to humans).

d. An excess of active hydrogen in the tank. This is caused by the

corrosion protective action of the anode.

Smelly water may be eliminated or reduced in some water heater

models by replacing the anode(s) with one of less active material, and

then chlorinating the water heater tank and all water lines. Contact

the local water heater supplier or a qualified service agency for

further information concerning an Anode Replacement Kit and this

chlorination treatment.
If the smelly water persists after the anode rod replacement and

chlorination treatment, we can only suggest that chlorination or aeration

of the water supply be considered to eliminate the water problem.
do not remove the anode rod leaving the tank unprotected. by

doing so, all warranty on the water heater tank is voided.

“aIr” In hot water faucets

HYDROGEN GAS: Hydrogen gas can be produced in a hot water

system that has not been used for a long period of time (generally

two weeks or more). Hydrogen gas is extremely flammable and

explosive. To prevent the possibility of injury under these conditions,

we recommend the hot water faucet, located farthest away, be

opened for several minutes before any electrical appliances

which are connected to the hot water system are used (such as a

dishwasher or washing machine). If hydrogen gas is present, there

will probably be an unusual sound similar to air escaping through the

pipe as the hot water faucet is opened. There must be no smoking

or open flame near the faucet at the time it is open.