Models 427 and 427R Installation

24

Wiring Connections

Before the kickplate/grille is installed, all necessary wiring

connections in the compressor compartment should be

completed.

If the dual installation heater kit is used with model 427 or

427R, the power supply leads should be connected

according to instructions included with the kit.

If a home alarm system is to be installed on the wine

storage unit, the connections should be made using the

logic supplied with the alarm specifications. Refer to the

illustration below for the appliance lead locations, and

refer to the following for color codes:

Normally open contacts: white with red stripe wire.

Normally closed contacts: white with blue stripe wire.

Common: gray with white stripe wire.

Use the

1

/

4

" (6) spade terminals or wire nuts provided to

make the proper wiring connections.

IMPORTANT NOTE:

If you are not responsible for alarm

system connection, this information should be supplied to

the home security system contractor.

HOME ALARM

CONNECTIONS

Home alarm connections.

The alarm circuit in the unit is intended as a low-

voltage, low-current device only. It should not be used

to switch line power.

Any unused terminals should be completely insulated

and all wires should be secured away from conductive

or moving components.