Appendix a – internal links and fuses – Solid State Logic 82S6XL090A User Manual

Page 19

Advertising
background image

Page 15

Appendix

Appendix A – Internal Links and Fuses

Fuses (Mains Inlet)

The mains inlet contains a single 1 amp 1.25" time delay fuse (SSL Part No. 35FJJ310). To change it disconnect the
mains inlet, then using a small screwdriver prise open the mains selector cover (see illustration on page 6.).
Under this cover is a removable carrier that contains the fuse – pull the carrier out to access the fuse inside. Test
and replace the fuse with the same type and value if necessary.

Internal Fuses

The internal power rails are also individually fused. These fuses should only be changed by suitably experienced
staff. They are listed below:

Fuses (629610X2 Power Regulator Card)

+48V FS1 - 500mA wire ended (SSL part No. 35F5E250)

Fuses (629612X1 Main Card)

–18V FS1 - 3 amp wire ended (SSL part No. 35F5E330)

–15V FS2 - 3 amp wire ended (SSL part No. 35F5E330)

+15V FS3 - 3 amp wire ended (SSL part No. 35F5E330)

+18V FS4 - 3 amp wire ended (SSL part No. 35F5E330)

+5V FS5 - 3 amp wire ended (SSL part No. 35F5E330)

Links

LK1 Compressor ‘Auto Attack’. Normally not fitted.

Fitting across pins 1 & 2 makes the compressor attack time program dependent when ‘Linear
Release’ is selected.
Fitting across pins 2 & 3 makes the compressor attack time program dependent normal
(logarithmic) release is selected.

LK2 Additional HF roll-off for Mic input transformer. Normally disabled by fitting across pins 1 & 2, fit

across pins 2 & 3 to enable.

LK3 Solder link. Links digital and analogue 0V. Do not remove.

LK4 Links chassis and analogue 0V. Normally fitted. Remove to increase impedance to 10Ω.

Advertising