Senco PC0968 User Manual

Page 12

Advertising
background image

12

TROUBLESHOOTING

Symptom 1. Motor will not run or restart.

Power cord not plugged in.

Motor/Pressure switch in “OFF” position.

Motor thermal overload switch has

tripped.

Fuse blown or circuit breaker has tripped.

Wrong gauge wire or length of extension

cord.

Air tank pressure exceeds motor/

pressure switch “cut-in” pressure.

Pressure release valve on motor/

pressure switch has not unloaded pump

head pressure.

Defective motor, motor capacitor, motor/

pressure switch, or check valve.

Plug cord into grounded outlet.

Move switch to “ON” position.

Turn air compressor off, wait until motor is cool, then check

motor circuit breaker.

Replace fuse or reset circuit breaker.

Check for proper fuse amperage.

Check for low voltage conditions.

Disconnect any other electrical appliances from circuit or

operate air compressor on its own branch circuit.

Check chart on page #10 for proper gauge wire and cord length.

Motor will start automatically when air tank pressure drops

below “cut-in” pressure of motor/pressure switch.

Bleed the line by moving the switch to the “Off” position.

Contact Senco Customer Service.

PROBABLE CAUSE

Motor/Pressure switch does not shut off motor when

air compressor reaches “cut-out” pressure and safety

relief valve activates.

Air compressor is incorrectly sized.

PROBABLE CAUSE

Defective pilot valve, the check valve is stuck open.

REMEDY

Move the motor/pressure switch to the “Off” position. If

the motor doesn’t shut off, unplug the air compressor. If

the electrical contacts are welded together, replace the

pressure switch.

Limit the air pressure to the capacity of the air

compressor. Either use a smaller tool or a larger air

compressor.

REMEDY

Remove, clean or replace.

Symptom 2. When in the Start/Stop option, motor runs continuously.

Symptom 3. Air continues to leak at motor/pressure switch release valve after motor stops.

Advertising