Make sure to place the charger on a dry, non-flammable

surface, such as metal or concrete.

Permanent Ring Connectors

1. To permanently attach to a battery, loosen and remove each nut

from the bolt at the battery terminals.

2. Connect the red POSITIVE connector ring to the POSITIVE

(POS, P, +) battery terminal.

3. Connect the black NEGATIVE connector ring to the NEGATIVE

(NEG, N, -) battery terminal.

4. Replace and tighten the nuts to secure.

5. Connect the ring connector cable assembly to the charger. Take

care to keep both wires and plug away from hot and moving parts.

6. Plug the charger power cord into a grounded 120V AC

electrical wall outlet. Make sure to place the charger on a dry,

non-flammable surface, such as metal or concrete.

Automatic Charging Mode

When an Automatic Charge is performed, the charger switches to the

Maintain Mode (see below) automatically after the battery is charged.

Aborted Charge

If charging cannot be completed normally, charging will abort. When

charging aborts, the charger’s output is shut off and the CHARGING

(yellow) LED will blink. To reset after an aborted charge, unplug

the charger from the AC outlet, wait a few moments, then plug it back in.

Desulfation Mode

Desulfation could take 10 hours. If desulfation fails, charging will abort

and the CHARGING

(yellow) LED will blink.

Completion of Charge

Charge completion is indicated by the CHARGED

(green) LED.

When lit, the charger has stopped charging and switched to the

Maintain Mode of operation.

Maintain Mode (Float-Mode Monitoring)

When the CHARGED

(green) LED is lit, the charger has started

Maintain Mode. In this mode, the charger keeps the battery fully

charged by delivering a small current when necessary. If the charger

has to provide its maximum maintain current for a continuous 12 hour