Enforcer – Controlled Products Systems Group SK-1123-FQ User Manual

Page 3

Advertising
background image

ENFORCER

F

LUSH

-M

OUNT

O

UTDOOR

A

CCESS

K

EYPAD

ENFORCER

F

LUSH

-M

OUNT

O

UTDOOR

A

CCESS

K

EYPAD

SECO-LARM U.S.A., Inc.

SECO-LARM U.S.A., Inc.

®

®

Option

Code Entry

Confirm

Function

8 1

1

#

1-second beep notifies the user to open the door when the output relay is activated
with the user code or request-to-exit button. Use with a locking device that gives no
sound when it activates, such as a magnetic lock.

0

#

The beep is disabled, replaced by 2 short beeps for valid user codes.

Option

Seconds

Confirm

Function

9

0

#

No door-propped-open alarm

1 to 999

#

Allowable time from 1 to 999 seconds that the door can be left open before the door-
propped-open alarm starts.

U

NIQUE

F

EATURES

12~24V AC/DC universal power – No programming or jumpers needed.

Mantrap (Interlock) – When used in pairs and with optional magnetic contacts, keypads can
protect an area with two doors by ensuring that only one door can be opened at a time. With the

mantrap function enabled, when a user opens one door, a signal is sent to disable the second
keypad, thereby preventing access through the second door until the first one is closed.

Output #1 inhibit control – Relay output #1 is typically used for a door strike. If the inhibit
control terminal is tied to ground, relay output #1 will not operate. This increases the security of

the protected premises during the time it is not expected to be occupied, such as during evening
or weekend hours. Control either by connecting output #2 or another switching device to the
inhibit control terminal (see example on page 6).

Door-forced-open warning – When used with an optional magnetic contact, the keypad will
beep continuously for 60 seconds if the door to the protected premises is forced open without
using a valid user code. The warning can be stopped any time by entering a valid code.

Door-propped-open warning – When used with an optional magnetic contact, the keypad
beeps continuously if the door is propped open for longer than the allowed open time. The

allowable open time is programmable from 1~999 seconds. The warning stops when the door
is reclosed.

Door-hold open mode – Output #2 can be programmed to hold the door open if it needs to
remain open for an extended length of time.

Auto or manual code entry checking:

Auto code entry checking mode – The keypad can be programmed to activate automatically
when the code is entered without the need to press the ―#‖ key. All user codes must be the

same length as the master code. This mode is more convenient for users.

Manual code entry checking mode – The user codes can vary in number of digits, and the

user must press the ―#‖ key when finished entering the code. This mode increases security.

Door auto relock (anti-tailgating) – The keypad will relock an open door either when the relock

time expires or immediately after the door is closed, depending on which occurs first. This
prevents unwanted ―tailgate‖ entries, which can happen if an unauthorized person tries to follow

an authorized person through the door.

Alarm system arm-disarm control – The keypad can be wired to an alarm control panel so that

an authorized user can arm or disarm an alarm system using the keypad.

Duress output – This NPN transistor open collector ground (-) output can be used to trigger a

silent alarm if an authorized user is forced under duress to use the keypad. The duress output is
activated by adding 2 to the first digit of any user code for output #1. When entered, the code

opens the protected door as it would normally, but a signal is quietly sent to a remote device to
call for help without alerting the unauthorized person.

Backlit keypad – The keypad is backlit to increase nighttime visibility. Backlight can be
programmed to remain off until all keys are pressed, or remain on at a dim setting, increasing to
full brightness when keys are pressed.

I

NSTALLER

P

ROGRAMMING

These functions should only be used by professional installers, as incorrect entries can disable the entire keypad function.

1. Enter Programming Mode

*Key in the Master Code. For first-time use, Master code is 0 0 0 0

2. Data Refresh

Enter Master Code

Confirm

Function

x x x x

Enter into programming mode

Option

Confirm

Function

8 9 0 1

#

Clears all previously stored data except for the master
code.

3. Configure Outputs

Option

Output Time

Confirm

Function

4 0

1 to 999

#

Output #1, momentary mode, from 1 to 999 seconds

4 1

#

Output #1, shunt mode (ON/OFF)

5 0

1 to 999

#

Output #2, momentary mode, from 1 to 999 seconds

5 1

#

Output #2, shunt mode (ON/OFF)

4. Wrong Code Lockout

Option

# of Tries

Confirm

Function

7 0

#

After 10 successive wrong codes, 30-second lockout

7 1

#

After 10 successive wrong codes, Duress activated

7 2

5 to 10

#

After 5 to 10 wrong codes, 15min lockout – Can reset with Master Code

7 6 0 0

#

No wrong code lockout

5. Door-Forced-Open Alarm

Option

Code Entry

Confirm

Function

8 0

1

#

Door-forced-open alarm is enabled

0

#

Door-forced-open alarm is disabled

6. Door Unlocked Annunciation

7. User Code Entry Mode

8. Keypress Beeps

9. Door-Propped-Open Alarm Timer

Confirm

Function

Exits programming mode, returns keypad to normal operation

10. Exit Programming Mode

(DEFAULT: 0 0 0 0 )

(DEFAULT: Momentary, 1-second output for both outputs)

(DEFAULT: 10 tries / 30 seconds)

(DEFAULT: Disabled)

(DEFAULT: On)

(DEFAULT: Manual)

(DEFAULT: On)

(DEFAULT: Off)

Option

Code Entry

Confirm

Function

8 3

1

#

Keypad beeps when a key is pressed.

0

#

Silent operation – keypad does not beep when a key is pressed unless in
programming mode.

Page 14

Page 3

Note: Output time must be entered for options 40 and 50.

Note: # of tries must be entered for option 72.

Note: Allowable time must be entered.

Option

Code Entry

Confirm

Function

8 2

1

#

Auto Entry Mode is selected. The # key that follows the user code is NOT required
in code entry. All User Codes MUST be set to the same digit length as the Master
Code, from 4-8 digits.

0

#

Manual Entry Mode is selected. The # key that follows the user code is required in
code entry. The User Codes can be any length between 4-8 digits.

Note: After entering
programming mode,
proceed to desired
programming option.

Advertising