Operation

Whenever power is applied the depth sounder
is active and water depth is displayed. If the
sonar signal does not show a bottom the display
will indicate “- -”. This can occur if the water is
aerated or the maximum depth is exceeded.
Note: The maximum depth decreases as boat
speed increases.

Alarms

Two types of alarms can be set; the Deep Alarm
and the Shallow Alarm. The Deep Alarm can be
set as high as 184 meters (605 feet) while the
Shallow Alarm can be set as low as 0.3 meter
(1 foot).

Whenever the water depth is greater than the
Deep Alarm setting and the alarm is enabled an
alarm will sound. The alarm repeats two short
beeps and alternates DAL and the water depth
on the display.

Whenever the water depth is less than the
Shallow Alarm setting and the alarm is enabled
an alarm will sound. The alarm repeats a single
long beep and alternates SAL and the water
depth on the display.

Alarms On/Off

Alarm settings are saved in memory.

To turn the alarm on, press the

"

(ON) key. An

arrow on the lower right corner of the display will
show (next to the Alarm Bell), to indicate that the
alarms are on.

120

#

OFF

ON

ON

^

^

V

To turn the alarms off, press the

#

(OFF) key.

The arrow in the lower right corner will
extinguish.

120

#

OFF

OFF

ON

^

V

V

Note:

The arrow will flash if alarms are turned

ON but the shallow alarm is individually

set to OFF. See next section.

Shallow Alarm

To set the shallow alarm:

1. Press the

"

key for three seconds. The

display will show:

Press for 3 Seconds

SAL

OFF

ON

ON

^

^

V

2. After a few seconds the display will indicate

the current Shallow Alarm depth setting.

88

51

3. Use the

"

and

#

keys to change the

value. If either key is held depressed for
more than one second the reading will
increase or decrease rapidly.

4. When the alarm is set, exit by pressing

both the

"

and

#

keys simultaneously.

Alternatively, if no keys are pressed for a
period of 5 seconds the normal depth
display will resume.

OFF

OFF

ON

ON

^

^

V

V

Press simultaneously to exit

Note:

If the reading is decreased to below

1.5 feet (or equivalent) the display will

show

!""

and the alarm will be disabled.

The alarm can also be disabled by

pressing both the

"

and

#

keys for 5

seconds. The word

!""

will be displayed

but the alarm depth will be retained for

future use.